Application of internal standardization in ICP-QMS through discrete sample introduction methodologies{{
نویسندگان
چکیده
Non-spectral matrix effects in ICP-MS are often corrected by the method of internal standardisation. In the case of discrete sampling a common algorithm refers to the ratio of either maxima or areas of both analyte and internal standard peaks. The current work describes a protocol for internal standardisation across the transient peak based on the calculation of analyte-to-internal standard ratio for every scan sweep. Thus, a new converted function, Every Sweep Internal Standardisation (ESIS) ratio versus time, is obtained. One required merit is a dynamic estimation of variable matrix influence. Three discrete sampling systems coupled to an ICP-QMS instrument have been studied (i.e., flow injection, air segmented discrete introduction and injection into an air carrier). Two internal standard introduction modes (i.e., continuous and pulse) have been evaluated. For continuous mode, the ESIS function has a profile similar to the sample injection peak while for the pulse mode it has approximately constant values only within a limited time interval. The ESIS zone of stability for the tested sampling systems has been critically evaluated. By ESIS protocol lower RSDs have been found than the common internal standardisation. The matrix correction efficiency achieved with ESIS ranged between 96%– 105%, 94%–106% and 93%–110% for an alcoholic beverage (alcohol content up to 40%), high salt content solution (NaCl up to 3%) and moss sample, respectively.
منابع مشابه
The performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†
The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC,...
متن کاملDetermination of I/I isotope ratios in liquid solutions and environmental soil samples by ICP-MS with hexapole collision cell
The determination of I in environmental samples at ultratrace levels is very difficult by ICP-MS due to a high noise caused by Xe impurities in argon plasma gas (interference of Xe), possible IH2 1 interference and an insufficient abundance ratio sensitivity of the ICP mass spectrometer for I/I isotope ratio measurement. A sensitive, powerful and fast analytical technique for iodine isotope rat...
متن کاملComparison method for uranium determination in ore sample by inductively coupled plasma optical emission spectrometry (ICP-OES).
A comparison method for the determination (without sample pre-concentration) of uranium in ore by inductively coupled plasma optical emission spectrometry (ICP-OES) has been performed. The experiments were conducted using three procedures: matrix matching, plasma optimization, and internal standardization for three emission lines of uranium. Three wavelengths of Sm were tested as internal stand...
متن کاملA Model for Standardization/Adaptation Strategy Selection in the Irans Multinational Companies (MNCs)
Purpose-The research aims at evaluating the standardization/adaptation of international marketing strategy in Iran multinational companies (MNCs) based a model in which the impact of external environmental variables on the marketing mix internal variables (i.e. Product, Promotion, Price and Place) is considered, while in the previous researches no attempt was done to examine the interdepende...
متن کاملInternal standardization--atomic spectrometry and geographical pattern recognition techniques for the multielement analysis and classification of Catalonian red wines.
Major and minor (K, P, Ca, Mg, Na, Fe, Mn, Zn, and Sr) and trace (Ba, Ni, Pb, V, Co, Cd, and Sb) elements from wine samples from the Denomination of Origin (DO) Empordà-Costa Brava (Catalonia, Spain) were analyzed by inductively coupled plasma atomic emission spectrometry (ICP-AES) and mass spectrometry (ICP-MS) respectively. Previously, a comparison of different calibration methodologies and s...
متن کامل