Concentrations of airborne culturable bacteria in 100 large US office buildings from the BASE study.
نویسندگان
چکیده
UNLABELLED This paper presents summary statistics of airborne culturable bacteria from the US Environmental Protection Agency Building Assessment Survey and Evaluation (BASE) study. Air samples were collected with single-stage, multiple-hole, agar impactors in 100 large office buildings in 1994-1998 to obtain normative data on indoor environmental quality. Bacterial concentrations were compared by incubation temperature, location, season, and climate zone. Forty-one percent of the samples were below the 2- or 5-min detection limits (18 or 7 CFU/m3, respectively) but less than 1% were overgrown. Mesophilic bacteria (30 degrees C) accounted for >95% of culturable bacteria, both indoors and outdoors. Average concentrations were higher outdoors, except for Gram-positive cocci, which were the only group that were significantly higher indoors (39 vs. 24 CFU/m3), and Gram-negative cocci, for which both concentrations were low and the difference were not significant. Outdoor concentrations of culturable bacteria were somewhat higher in winter (194 vs.165 CFU/m3), and the two dominant outdoor groups were unknown bacteria and Gram-positive rods. Conversely, indoor concentrations were significantly higher in summer (116 vs. 87 CFU/m3), consisting primarily of unknown bacteria and Gram-positive cocci. Bacterial concentrations were within the ranges reported in previous studies of non-problem buildings, and the extreme aggregated indoor concentrations (e.g. the 90th percentile, 175 CFU/m3) of these 100 representative buildings may serve as upper bounds to develop interpretation guidelines for office environments and similar non-manufacturing workplaces in various climate zones. PRACTICAL IMPLICATIONS The Building Assessment Survey and Evaluation (BASE) study was one of the most comprehensive investigations of indoor environmental quality in which a standardized protocol was used to measure bioaerosols in 100 typical US office buildings. The information on the indoor and outdoor concentrations of airborne bacteria in different climate zones during the heating and cooling seasons has expanded the baseline data available for interpretation of measurements from building investigations. With suggested refinements, the BASE protocol may serve as a guide for future studies of bioaerosol concentrations, building characteristics, and occupant perceptions of the indoor environment.
منابع مشابه
Exposure of workers to airborne microorganisms in open-air swine houses.
This study quantified the levels of airborne microorganisms in six swine farms with more than 10,000 pigs in subtropical Taiwan. We evaluated breeding, growing, and finishing stalls, which were primarily open-air buildings, as well as partially enclosed farrowing and nursery piggeries. Airborne culturable bacteria, gram-negative bacteria, and fungi were placed on appropriate media by using an a...
متن کاملPopulations and determinants of airborne fungi in large office buildings.
Bioaerosol concentrations in office environments and their roles in causing building-related symptoms have drawn much attention in recent years. Most bioaerosol studies have been cross-sectional. We conducted a longitudinal study to examine the characteristics of airborne fungal populations and correlations with other environmental parameters in office environments. We investigated four office ...
متن کاملProfiles of airborne fungi in buildings and outdoor environments in the United States.
We examined 12,026 fungal air samples (9,619 indoor samples and 2,407 outdoor samples) from 1,717 buildings located across the United States; these samples were collected during indoor air quality investigations performed from 1996 to 1998. For all buildings, both indoor and outdoor air samples were collected with an Andersen N6 sampler. The culturable airborne fungal concentrations in indoor a...
متن کاملStudent absenteeism and the comparisons of two sampling procedures for culturable bioaerosol measurement in classrooms with and without upper room ultraviolet germicidal irradiation devices
Upper room ultraviolet germicidal irradiance (UVGI) has been shown to reduce the concentration of bioaerosols in controlled chambers. However, there is a lack of experimental results on the reduction of bioaerosol concentrations by UVGI devices in actual uncontrolled buildings. This study was carried out in an American elementary school in the Midwest. Two sampling procedures were carried out i...
متن کاملAir samplings in a Campylobacter jejuni positive laying hen flock.
The air in laying hen houses contains high concentrations of airborne bacteria. The numbers of these bacteria can be influenced by the efficiency of the chosen sampling method. In the presented study, AGI-30 Impingers and the Coriolis(®)µ air Sampler were compared in terms of their efficiency in sampling aerobic mesophilic bacteria in a laying hen house. Measurements were conducted in a laying ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Indoor air
دوره 15 Suppl 9 شماره
صفحات -
تاریخ انتشار 2005