The effect of different amines added to eluents as silanol masking agents on the chromatographic behavior of some diuretics in reversed-phase high-performance liquid chromatography using C18 packings.

نویسندگان

  • A I Gasco-López
  • A Santos-Montes
  • R Izquierdo-Hornillos
چکیده

A preliminary gradient separation in reversed-phase liquid chromatography of a mixture of 25 solutes (diuretics, probenecide, and atenolol) is carried out using several C18 columns and an aqueous phosphoric acid solution (pH 3.2)-acetonitrile mobile phase as a control. Using this separation, the chromatographic behavior of these solutes is studied using 11 water-soluble primary, secondary, and tertiary amine modifiers in the range of 0.7-7.5 mM and a Spherisorb C18 column. This study reveals the presence in the complex sample of two groups of solutes with positive (five typical solutes showed improvements in peak symmetry and retention) or negative responses using these amines as mobile phase modifiers. After experimentation in the presence of amines, these differences are related to solute structure. Hexylamine is found to be an effective masking agent of silanols because of its structure and small required concentration. On these bases, the silanophilic and hydrophobic character of typical solutes and several C18 packings are evaluated under isocratic elution and a relative effectiveness index for amines, and a method for their assessment is proposed. The role of the amine structure on solute retention and the importance of selecting amines of suitable hydrophobic character, molecular geometry, and concentration is discussed. A model of the formation and stabilization of the silanol-amine complex based on hydrophobic and ionic interactions is also proposed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of ionic liquid additives to mobile phase on separation and system efficiency for HPLC of selected alkaloids on different stationary phases.

The silica-based stationary phases with favorable physical characteristics are the most popular in liquid chromatography. However, there are several problems with silica-based materials: severe peak tailing in the chromatography of basic compounds, non-reproducibility for the same chemistry columns, and limited pH stability. Ionic liquids (ILs) as mobile phase components can reduce peak tailing...

متن کامل

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

متن کامل

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

متن کامل

Preparation and chromatographic evaluation of columns for reversed-phase liquid chromatography.

Column selection in reversed-phase liquid chromatography is still not a straightforward process. In this study, we have evaluated and compared the performance of several traditional C18 phases with polar-modified phases and found distinct differences in the chromatographic behavior between two groups, as well as a high degree of variability within each group. The polar-endcapped phases exhibit ...

متن کامل

Analysis of Basic Psychotropic Drugs in Biological Fluids and Tissues by Reversed-phase High Performance Liquid Chromatography.

The review of the RP HPLC analysis of basic psychotropic drugs is presented. It contains sample preparation methods with centrifugation, protein precipitation, liquid-liquid extraction (LLE), dispersive liquid-liquid microextraction (DLLME), solid-phase extraction (SPE), solid-phase microextraction (SPME), microwave-assisted extraction (MAE) and RP-HPLC analysis. Chromatographic behavior of bas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 35 11  شماره 

صفحات  -

تاریخ انتشار 1997