White blood cell differential counts in severely leukopenic samples: a comparative analysis of different solutions available in modern laboratory hematology

نویسندگان

  • Ah Hyun Kim
  • Wonbae Lee
  • Myungshin Kim
  • Yonggoo Kim
  • Kyungja Han
چکیده

BACKGROUND We evaluated the efficacy of white blood cell (WBC) differential counts in severely leukopenic samples by the Hematoflow method and by automated hematology analyzers and compared the results with manual counts. METHODS EDTA-anticoagulated blood samples (175 samples) with WBC counts of 40-990/µL were selected. Hematoflow differential counts were performed in duplicates employing flow cytometry using the CytoDiff reagent and analysis software. Differential counts were also performed using the DxH 800 (Beckman Coulter) and XE-2100 (Sysmex) automated hematology analyzers. The sum of the manual counts by a hematology technician and a resident were used as the manual counts. RESULTS The total analysis time and hands-on time required by the Hematoflow method were shorter than those required by manual counting. Hematoflow counts were reproducible, showed a good correlation with automated analyzers, and also showed strong correlation with manual counts (r > 0.8) in neutrophils, lymphocytes, and monocytes. None of the cases containing less than 4% blasts as analyzed by the Hematoflow method had blasts in the manual counts, but 8 cases of 21 cases (38.1%) with over 4% blasts by Hematoflow had blasts in manual counts. CONCLUSION Hematoflow counts of severely leukopenic samples were reproducible and showed a good correlation with manual counts in terms of neutrophil, lymphocyte, and monocyte counts. The Hematoflow method also detected the presence of blasts. Manual slide review is recommended when over 4% blasts are found by Hematoflow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of early post-transplant leukocyte recovery using the undiluted erythrocyte lysing technique.

The undiluted erythrocyte lysing technique was evaluated to see if it provides more accurate total leukocyte counts and differential leukocyte counts of severely leukopenic blood samples, in order to detect the onset of hematopoietic recovery after stem cell transplantation. Leukocyte counts using the conventional automated cell counting technique were found to be inaccurate, especially in bloo...

متن کامل

Reliable, Accurate Determination of the Leukocyte Differential of Leukopenic Samples by Using Hematoflow Method

BACKGROUND Hematology analyzers may ineffectively recognize abnormal cells, and manual differential counts may be imprecise for leukopenic samples. We evaluated the efficacy of the Hematoflow method for determining the leukocyte differential in leukopenic samples and compared this method with the manual differential method. METHODS We selected 249 blood samples from 167 patients with leukopen...

متن کامل

Evaluation of total and differential white blood cell counts in workers exposed to lead

Introduction: Lead is a toxic heavy metal that has adverse health effects on blood parameters. About 80% of lead produced is used in batteries, especially vehicle batteries. Therefore, the present study aimed to assess the hematological changes, including total and differential white blood cell (WBC) counts in battery workers exposed to lead, and compare with the non-exposed group. Materials a...

متن کامل

Performance evaluation of the ADVIA 2120 hematology analyzer: an international multicenter clinical trial.

Automated cell counters are widely used in modern clinical laboratories to provide reliable, fast, and cost-effective complete blood counts (CBCs), white blood cell differentials, and reticulocyte measurements. In addition, some advanced instruments provide novel parameters, such as the hemoglobin content of reticulocytes or the percentage of hypochromic cells, and are capable of analysis of a ...

متن کامل

Effect of carvacrol on pulmonary function tests, and total and differential white blood cell counts in healthy volunteers: A randomized clinical trial

Objective: This is the first study to evaluate the effect of carvacrol on pulmonary function tests (PFT), and total and differential white blood cell (WBC) counts in healthy volunteers. Materials and Methods: Thirty healthy volunteers were recruited based on the inclusion and exclusion criteria. The subjects were treated with two doses of carvacrol (1 and 2 mg/kg/day) for 1 month. Total and di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2014