The risk of neurovascular injury in minimally invasive plate osteosynthesis (MIPO) when using a distal tibia anterolateral plate: a cadaver study.

نویسندگان

  • S Lidder
  • S Masterson
  • C Grechenig
  • H Clement
  • A Gänsslen
  • S Grechenig
چکیده

PURPOSE OF THE STUDY Percutaneous plating of the distal tibia via a limited incision is an accepted technique of osteosynthesis for extra-articular and simple intra-articular distal tibia fractures. The aim of this study was to analyze structures that are at risk during this approach. MATERIAL AND METHODS Thirteen unpaired adult lower limbs were used for this study. Thirteen, 15-hole LCP anterolateral distal tibial plates were percutaneously inserted according to the recommended technique. Dissection was performed to examine the relation of the superficial and deep peroneal nerves and anterior tibial artery relative to the plate. RESULTS The superficial peroneal nerve was found to cross the vertical limb of the LCP plate at a mean distance of 63 mm (screw hole five) but with a wide range of 21 to 105 mm. The neurovascular bundle (deep peroneal nerve and anterior tibial artery) crossed the plate at a mean of 76 mm (screw hole six) but also with a wide range of 38 to 138 mm. The zone of danger of the neurovascular structures ranges from 21 to 138 mm from the tibial plafond. In one specimen, a significant branch of the deep peroneal nerve was found to be entrapped under the plate. CONCLUSION Caution is advised when using anterolateral minimally invasive technique for plate insertion and screw placement in the distal tibia due to great variability in the neurovascular structures that course distally in the lower leg and cross the ankle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures

Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...

متن کامل

Comparative study of intramedullary interlocking nailing and minimally invasive percutaneous plate osteosynthesis (MIPO) in extra articular distal tibial fracture

Introduction: Tibia is one of the most commonly fractured long bone of the body. Distal tibia fractures are primarily located within a square based on the width of the distal tibia. Treatment of distal tibia fracture is challenging because of its unique anatomical characteristics of subcutaneous location with precarious blood supply and proximity to the ankle joint. Minimally invasive plate ost...

متن کامل

Minimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture

Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology of distal t...

متن کامل

The risk of iatrogenic injury to the deep peroneal nerve in minimally invasive osteosynthesis of the tibia with the less invasive stabilisation system: a cadaver study.

Percutaneous stabilisation of tibial fractures by locking plates has become an accepted form of osteosynthesis. A potential disadvantage of this technique is the risk of damage to the neurovascular bundles in the anterior and peroneal compartments. Our aim in this anatomical study was to examine the relationship of the deep peroneal nerve to a percutaneously-inserted Less Invasive Stabilisation...

متن کامل

Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report.

Minimally Invasive Plate Osteosynthesis (MIPO) has gained popularity with satisfactory clinical outcomes in the treatment of long bone fractures. MIPO for humeral shaft fractures, however, could be a surgically dangerous procedure because of the risk of radial nerve injury. An anatomical study was performed to evaluate the feasibility of MIPO for the humeral shaft fractures, and to study the re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca

دوره 81 5  شماره 

صفحات  -

تاریخ انتشار 2014