Neurophysiology of cochlear implant users II: comparison among speech perception, dynamic range, and physiological measures.

نویسندگان

  • Jill B Firszt
  • Ron D Chambers And
  • Nina Kraus
چکیده

OBJECTIVE The overall objective of this study was to relate electrically evoked potentials recorded from different levels of the auditory pathway with behavioral measures obtained from adult cochlear implant subjects. The hypothesis was that adult recipients of cochlear implants who have open-set speech perception and those recipients with no open-set speech perception would differ in their neurophysiologic responses recorded at one or more levels of the auditory pathway. DESIGN The subjects were 11 adults implanted with the Clarion cochlear implant. The electrical auditory brainstem response (EABR, Wave V), electrical auditory middle latency response (EAMLR, Na-Pa complex), and the electrical late auditory response (ELAR, N1-P2 complex), were recorded from three intra-cochlear electrodes. The stimuli used to record the evoked potentials varied in rate and amplitude. Behavioral measures (between threshold and upper limit of comfortable loudness) were used to define the subject's dynamic range at the different stimulus rates. Word and sentence recognition tests evaluated subjects' speech perception in quiet and noise. Evoked potential and behavioral measures were examined for statistical significance using analysis of variance for repeated measures and correlational analyses. RESULTS Subjects without open-set speech recognition demonstrated 1) poorly formed or absent evoked potential responses, 2) reduced behavioral dynamic ranges, 3) lack of change in the size of the dynamic range with a change in stimulus rate, and 4) longer periods of auditory deprivation. The variables that differentiated the best performers included 1) presence of responses at all three levels of the auditory pathway, with large normalized amplitudes for the EAMLR, 2) lower evoked potential thresholds for the Na-Pa complex, 3) relatively large dynamic ranges, and 4) changes in the size of the dynamic range with changes in stimulus rate. CONCLUSIONS In this study, the inability to follow changes in the temporal characteristics of the stimulus was associated with poor speech perception performance. Results also illustrate that variability in speech perception scores of cochlear implant recipients relates to neurophysiologic responses at higher cortical levels of the auditory pathway. Presumably, limited neural synchrony for elicitation of electrophysiologic responses underlies limited speech perception. Results confirm that neural encoding with electrical stimulation must provide sufficient physiologic responses of the central nervous system to perceive speech through a cochlear implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between Auditory Spectral Resolution and Speech Perception in Children with Cochlear Implants

Background: Variability in speech performance is a major concern for children with cochlear implants (CIs). Spectral resolution is an important acoustic component in speech perception. Considerable variability and limitations of spectral resolution in children with CIs may lead to individual differences in speech performance. The aim of this study was to assess the correlation between auditory ...

متن کامل

Speech Perception in Children with Cochlear Implants

Cochlear implants provide access to the speech signal in children with hearing loss that often cannot benefit from acoustic hearing aids. However, despite the numerous positive results in pediatric cochlear implantation, published data still indicated a wide range of performance among implant recipients. Hence, a need to study the possible variables that can affect performance, could account fo...

متن کامل

Assessment and improvement of sound quality in cochlear implant users

OBJECTIVES Cochlear implants (CIs) have successfully provided speech perception to individuals with sensorineural hearing loss. Recent research has focused on more challenging acoustic stimuli such as music and voice emotion. The purpose of this review is to evaluate and describe sound quality in CI users with the purposes of summarizing novel findings and crucial information about how CI users...

متن کامل

Relationship between Working Memory, Auditory Perception and Speech Intelligibility in Cochlear Implanted Children of Elementary School

Objectives: This study examined the relationship between working and short-term memory performance, and their effects on cochlear implant outcomes (speech perception and speech production) in cochlear implanted children aged 7-13 years. The study also compared the memory performance of cochlear implanted children with their normal hearing peers. Methods: Thirty-one cochlear impl...

متن کامل

The effect of reduced dynamic range on speech understanding: implications for patients with cochlear implants.

OBJECTIVE To determine the effect of reduced dynamic range on speech understanding when the speech signals are processed in a manner similar to a 6-channel cochlear implant speech processor. DESIGN Signals were processed in a manner similar to a 6-channel cochlear implant processor and output as a sum of sine waves with frequencies equal to the center frequencies of the analysis filters. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ear and hearing

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2002