Resampling approach for determination of the method for reference interval calculation in clinical laboratory practice.

نویسندگان

  • Igor Y Pavlov
  • Andrew R Wilson
  • Julio C Delgado
چکیده

Reference intervals (RI) play a key role in clinical interpretation of laboratory test results. Numerous articles are devoted to analyzing and discussing various methods of RI determination. The two most widely used approaches are the parametric method, which assumes data normality, and a nonparametric, rank-based procedure. The decision about which method to use is usually made arbitrarily. The goal of this study was to demonstrate that using a resampling approach for the comparison of RI determination techniques could help researchers select the right procedure. Three methods of RI calculation-parametric, transformed parametric, and quantile-based bootstrapping-were applied to multiple random samples drawn from 81 values of complement factor B observations and from a computer-simulated normally distributed population. It was shown that differences in RI between legitimate methods could be up to 20% and even more. The transformed parametric method was found to be the best method for the calculation of RI of non-normally distributed factor B estimations, producing an unbiased RI and the lowest confidence limits and interquartile ranges. For a simulated Gaussian population, parametric calculations, as expected, were the best; quantile-based bootstrapping produced biased results at low sample sizes, and the transformed parametric method generated heavily biased RI. The resampling approach could help compare different RI calculation methods. An algorithm showing a resampling procedure for choosing the appropriate method for RI calculations is included.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

Reference Interval of Cerebrospinal Fluid-Adenosine Deaminase Enzyme in Apparently Healthy Subjects- A Retrospective Study in India

Background and Aims: The aim of the present study was to re-evaluate the upper limit of normal range (ULN) for adenosine deaminase (ADA) level in cerebrospinal fluid (CSF) of healthy subjects in Indian population. Materials and Methods: Posteriori strategy was used for reference population selection. Individuals whose CSF samples had come to the laboratory of Bhatia Hospital, Mumbai (India) ...

متن کامل

Determination of the best-fitting reference orbit for a LEO satellite using the Lagrange coefficients

Linearization of the nonlinear equations and iterative solution is the most well-known scheme in many engineering problems. For geodetic applications of the LEO satellites, e.g. the Earth’s gravity field recovery, one needs to provide an initial guess of the satellite location or the so-called reference orbit. Numerical integration can be utilized for generating the reference orbit if a satelli...

متن کامل

Comparison of different empirical methods for estimating ddaily reference evapotranspiration in the humid cold climate (case study: Borujen, Shahrekord, Koohrang and Lordegan)

The proposed method for calculation of potential evapotranspiration is Penman-Monteith FAO method, but there are other methods that require less meteorological data but estimates close to the FAO Penman-Monteith method in different climatic conditions.  Performance evaluation of these methods on the same basis is prerequisite for selecting an alternative approach in accordance with available da...

متن کامل

Establishment of Reference Interval for Homeostasis Model Assessment of Insulin Resistance in Healthy Adult Males: a Pilot Study in Alexandria Governorate, Egypt

Abstract Objective: Homeostasis model assessment of insulin resistance (HOMA-IR) is a simple and practical method for estimation of insulin resistance (IR), but a reliable reference interval (RI) of HOMA-IR is needed to deduce the threshold level to define IR. This RI has been controversial in different populations and even more divergent when considering factors like age, gender and body mass...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and vaccine immunology : CVI

دوره 17 8  شماره 

صفحات  -

تاریخ انتشار 2010