Non-contact tonometry in the postoperative eye.

نویسنده

  • S A Vernon
چکیده

The Keeler Pulsair non-contact tonometer was compared with the Goldmann applanation tonometer in a series of 48 eyes after operation. A correlation coefficient of 0.92 (p less than 0.001) was found between the two instruments, with the Pulsair having a statistically significant tendency to overread the Goldmann slightly in this situation. The Pulsair was, however, shown to be effective in the identification of postoperative ocular hypertension with a high degree of sensitivity and specificity and good patient compliance, while reducing the risk of cross infection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction: Ocular Surface Displacement with and without Contact Lenses during Non-Contact Tonometry

PURPOSE To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft contact lenses (CLs). METHODS One eye each in 21 subjects was studied. The cornea was photographed usin...

متن کامل

Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.

BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

فشار داخل چشمی تهران -1381

Background: The aim of this study was to provide data, on the distribution or intraocular pressure (IOP) in Tehran population. Materials and Methods: Through a population-based, cross-sectional study, a total of 4565 Tehran citizens were studied in the Tehran Eye Study. The findings of the participants (n=3834) 10 years and older free of glaucoma diagnosis or suspicion who had undergone applana...

متن کامل

Endonasal endoscopic orbital decompression in patients with Graves' ophthalmopathy.

AIM To present the results of endonasal endoscopic orbital decompression in patients with Graves' ophthalmopathy. METHODS Endonasal endoscopic orbital decompression was performed in 32 orbits of 21 patients with Graves' ophthalmopathy. In 17 patients the surgery was performed because of active ophthalmopathy non-responsive to conservative treatment, and in 4 patients for esthetic reasons. Pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 73 4  شماره 

صفحات  -

تاریخ انتشار 1989