Verification of computerized treatment planning for HDR 192Ir brachytherapy for gynaecological cancer.

نویسندگان

  • Saeed Ahmad Buzdar
  • Muhammad Asghar Gadhi
  • Muhammad Afzal Rao
  • Naeem Ahmad Laghari
  • Mohammad Anees
چکیده

Treatment planning in both teletherapy and brachytherapy is time consuming practice but accurate determination of planning parameters is more important. This paper aims to verify the dose delivery time for the treatment of vaginal cancer, which is a vital parameter of High Dose Rate (HDR) brachytherapy treatment planning. Treatment time has been calculated by the computerized treatment planning system (ABACUS 3.1), and then it has been compared with the manually calculated time. The results obtained are in good agreement. Independent verification of nominal time by two different protocols assures the quality of treatment. This should always be practiced to increase the accuracy of treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verification of delivered dose to the Lips carcinoma tumors with HDR brachytherapy sources: 192Ir and 60CO in an exclusive plexiglass Phantom.

Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...

متن کامل

Comparison the treatment time of cobalt and iridium sources in HDR brachytherapy

Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...

متن کامل

HDR and PDR 192Ir source activity control procedures, as the part of the quality assurance system at Brachytherapy Department of Greater Poland Cancer Centre

PURPOSE One of the main causes of treatment failures in brachytherapy is incorrect source strength specification in planning system or treatment delivery console. Source strength control is the only scheme to avoid such mistakes. The main aim of this work was to present results of three years of HDR and PDR sources activity control. MATERIAL AND METHODS Study was based on data from 14 192Ir H...

متن کامل

2nd FY Khoo Memorial Lecture. Brachytherapy--one man's meat, a personal journey in radiation oncology.

The Lecture covers the author's personal experience in brachytherapy in radiation oncology, beginning with low-dose rate (LDR) treatments using 226Ra "hot" sources, in the 1960s and early 1970s, through manual afterloading for treating gynaecological cancers with the same sources in the 1970s and 1980s, to high-dose rate (HDR) remote afterloading on a microSelectron HDR machine, from 1989 on. T...

متن کامل

A comparative assessment of inhomogeneity and finite patient dimension effects in 60Co and 192Ir high-dose-rate brachytherapy

Purpose To perform a comparative study of heterogeneities and finite patient dimension effects in 60Co and 192Ir high-dose-rate (HDR) brachytherapy. Material and methods Clinically equivalent plans were prepared for 19 cases (8 breast, 5 esophagus, 6 gynecologic) using the Ir2.A85-2 and the Co0.A86 HDR sources, with a TG-43 based treatment planning system (TPS). Phase space files were obtaine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JPMA. The Journal of the Pakistan Medical Association

دوره 59 2  شماره 

صفحات  -

تاریخ انتشار 2009