Iterative Off-resonance and Signal Decay Correction for Improved Multi-echo Imaging in MRI

نویسندگان

  • Tobias Knopp
  • Holger Eggers
  • Hannes Dahnke
  • Jürgen Prestin
  • Julien Sénégas
چکیده

Local deviations of the main field and signal decay due to transverse relaxation lead to perturbations of the Fourier encoding commonly applied in magnetic resonance imaging. Hence, images acquired with trajectories having long readout times suffer from artefacts such as blurring, geometric distortion, and intensity inhomogeneity. These effects can be corrected by means of iterative reconstruction algorithms, provided a field map and a relaxation map are available. Recently, a fast griddingbased approach to field inhomogeneity correction was proposed. In this work, this algorithm is extended to also handle the signal decay due to relaxation. It is then embedded in a novel fixedpoint iteration algorithm that allows for the joint estimation of the field map, relaxation map, and echo images from a single multi-echo acquisition. This joint estimation approach enables the application of fast acquisition trajectories in multi-echo imaging experiments, such as spiral and echo planar, while avoiding artefacts in the reconstruction of the echo images, the field map, and the relaxation map. Since the method dispenses with the acquisition of a separate calibration scan, an appreciable overall reduction in scan time can be achieved. The evaluation of the proposed algorithm in simulations and in-vivo experiments shows a significant improvement in the reconstruction of the echo images and the estimation of the relaxation map, as compared to the standard case, where no correction is applied. The demonstrated rapid convergence of the fixed-point iteration algorithm together with the computational efficiency of the gridding-based reconstruction keeps the overall computation time reasonable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

متن کامل

Potential positive MRI contrast agent based on PVP-grafted superparamagnetic iron oxide nanoparticles with various repetition times

Objective(s): The present study aimed to evaluate the capability of synthesized and modified superparamagnetic iron oxide nanoparticles (SPIONs) as the positive contrast agent in magnetic resonance imaging (MRI) by investigating the effect of repetition time (TR) on the MRI signal intensity. Materials and Methods: SPIONs were synthesized using the co-precipitation method, and their surfac...

متن کامل

High-resolution diffusion MRI at 7T using a three-dimensional multi-slab acquisition

High-resolution diffusion MRI can provide the ability to resolve small brain structures, enabling investigations of detailed white matter architecture. A major challenge for in vivo high-resolution diffusion MRI is the low signal-to-noise ratio. In this work, we combine two highly compatible methods, ultra-high field and three-dimensional multi-slab acquisition to improve the SNR of high-resolu...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007