Reproducibility of Middle Cerebral Artery Stenosis Measurements by DSA: Comparison of the NASCET and WASID Methods

نویسندگان

  • Luguang Chen
  • Qian Zhan
  • Chao Ma
  • Qi Liu
  • Xuefeng Zhang
  • Xia Tian
  • Yuanliang Jiang
  • Yinmei Dong
  • Shiyue Chen
  • Jianping Lu
  • Rex Eugene Jung
چکیده

PURPOSE To evaluate the intra- and inter-observer variability of the North American Symptomatic Carotid Endarterectomy Trial (NASCET) and Warfarin-Aspirin Symptomatic Intracranial Disease (WASID) criteria for the evaluation of middle cerebral artery (MCA) stenosis using digital subtraction angiography (DSA). MATERIALS AND METHODS DSA images of 114 cases with 131 stenotic MCAs were retrospectively analyzed. Two radiologists and a researcher measured the degree of MCA stenosis independently using both NASCET and WASID methods. To determine intra-observer agreement, all the observers reevaluated the degree of MCA stenosis 4 weeks later. The linear relation and coefficient of variation (CV) between the measurements made by the two methods were assessed by correlation coefficient and multi-factor analysis of variance (ANOVA), respectively. Intra- and inter-observer variability of the two methods was evaluated by intraclass correlation coefficient (ICC), Spearman's R value, Pearson correlation coefficient and Bland-Altman plots. RESULTS Despite the fact that the degree of MCA stenosis measured by NASCET was lower than measured using the WASID method, there was good linear correlation between the measurements made by the two methods (for the mean measurements of the 3 observers, NASCET% = 0.891 × WASID% - 1.89%; ICC, Spearman's R value and Pearson correlation were 0.874, 0.855, and 0.874, respectively). The CVs of both intra- and inter-observer measurements of MCA stenosis using WASID were significantly lower than that using NASCET confirmed by the multi-factor ANOVA results, which showed only the measurement methods of MCA stenosis had significant effects on the CVs both in intra- and inter-observer measurements (both P values < 0.001). Intra-observer measurements showed good or excellent agreement with respect to WASID and NASCET evaluation (ICC, 0.656 to 0.817 and 0.635 to 0.761, respectively). Good agreement for the WASID evaluation (ICC, 0.592 to 0.628) and for the NASCET evaluation (ICC, 0.529 to 0.568) was observed for inter-observer measurements. Bland-Altman plots demonstrated that the WASID method had better reproducibility and intra-observer agreement than NASCET method for evaluating MCA stenosis. CONCLUSION Both NASCET and WASID methods have an acceptable level of agreement; however, the WASID method had better reproducibility for the evaluation of MCA stenosis, and thus the WASID method may serve as a standard for measuring the degree of MCA stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

Measuring carotid stenosis on contrast-enhanced magnetic resonance angiography: diagnostic performance and reproducibility of 3 different methods.

BACKGROUND AND PURPOSE The aim of this study was to compare diagnostic performance and reproducibility of 3 different methods of quantifying stenosis on contrast-enhanced magnetic resonance angiography (CEMRA), with intra-arterial digital subtraction angiography (DSA) as the reference standard. METHODS 167 symptomatic patients scheduled for DSA, after screening Doppler ultrasound, were prospe...

متن کامل

Measurement of carotid stenosis using duplex ultrasonography with a microconvex array transducer: a validation with cerebral angiography.

BACKGROUND We aimed to evaluate the validity of duplex ultrasonography (DUS) using a microconvex array transducer (MAT) with enhanced flow imaging (EFI) for visualization of the distal, internal carotid artery (ICA) and the accurate assessment of ICA stenosis. METHODS Patients who underwent both DUS and digital subtraction angiography (DSA) were registered for this study. DUS was performed by...

متن کامل

Large-vessel stenosis in the patients with ischemic stroke in Iran: Prevalence, pattern, and risk factors.

BACKGROUND Large artery disease (LAD) is a common cause of stroke, but a little is known regarding its role in Iranian stroke patients. The current study investigates the prevalence and risk factors for cervicocephalic arterial stenosis in the patients with ischemic stroke using digital subtraction angiography (DSA). METHODS This was a prospective cross-sectional study performed in hospitals ...

متن کامل

Prognostic Value and Reproducibility of Measurements of Carotid Stenosis A Comparison of Three Methods on 1001 Angiograms

Background and Purpose The use of three methods of measuring carotid stenosis, which produce different values on the same angiograms, has caused confusion and reduced the generalizability of the results of research. If the results of future studies are to be properly applied to clinical practice, and if noninvasive methods of imaging are to be properly validated against angiography, a single, s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015