Fluctuation of Spuriously Elevated Troponin I: A Case Report
نویسندگان
چکیده
Serum troponin is a useful laboratory study for the diagnosis of acute myocardial infarction. However, elevations can also be seen in a variety of other diseases processes. Falsely positive troponin values caused by interference with current troponin assays have been reported. We report a unique case that demonstrates the fluctuation of falsely elevated troponin correlating with hemoglobin, serving as a marker of heterophile antibody levels. A 74-year-old gentleman presented to our Emergency Department with a several-day history of increasing shortness of breath associated with a new-onset chest pain and a troponin I level of 77.28 ng/mL. Throughout his stay, fluctuations in measured troponin levels correlated strongly with fluctuations in hemoglobin levels. Several investigations confirmed false elevated troponin levels secondary to heterophile antibody interference. We conclude that hemoglobin trending in our patient represented a surrogate measure of his heterophile antibody titers with time and that fluctuations in these levels correlated with respective fluctuations in the falsely elevated troponin levels.
منابع مشابه
Misleading Elevation of Troponin T caused by Polymyositis
BACKGROUND Elevations of cardiac enzymes are commonly used to indicate myocardial ischemia, but they can be elevated due to other conditions. Different forms of Troponin (cTnT, sTnT, cTnI), can cause cross-reactivity in the Troponin T assay, leading to false positives. This report describes a patient with polymyositis who had elevated Troponin T, but no cardiac abnormalities. The purpose is to ...
متن کاملSerum troponin I as an indicator of myocarditis in lambs affected with foot and mouth disease
Foot and mouth disease (FMD) is a highly contagious viral disease of cloven-hooved livestock and wildlife results to relatively high mortality in young animals. Despite the numerous reports of FMD-related death in neonates, there is little data available on various aspects of FMD in lambs. This report describes myocarditis associated with FMD in five, one week to three months old lambs. The lam...
متن کاملEvaluation of Troponin-T level in Neonate with Mechanical Ventilation
Introduction: Troponin- T is the best biological marker of heart injuries, that isn’t affected by sex, age, birth weight and gestational age. Myocardial damage in infancy is a risk factor eventual cardiac disease. This study carried out for cardiac evaluation of neonates with mechanical ventilation by Troponin T. Methods: This case-control study carried out on 60 infants that were admitte...
متن کاملA Rare Case of Acute Myocardial Infarction Associated with Arsenic Poisoning
Background: Arsenic toxicity as a result of consumption of hair removal agent has been rarely seen in last few years in comparison with the past. Case Presentation: In this case report, we presented a middle age woman referred to medical toxicology department due to epigastric pain and diarrhea following ingestion of hair removal agent. Urinary test for arsenic was positive. ECG changes and ele...
متن کاملمقایسه سطح تروپونین I در زنان مبتلا به پره اکلامپسی و فشارخون بارداری با زنان باردار با فشار خون نرمال
Background and purpose: Hypertensive disorders of pregnancy are still one of the major issues in obstetrics. So far, few studies are conducted on the troponin I level of pregnant women and preeclampsia but their results are not conclusive. In this study the troponin levels were compared between patients with severe preeclampsia, mild preeclampsia, gestational hypertension, and normal blood pres...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012