Analysis of regional wall motion during contrast-enhanced dobutamine stress echocardiography: effect of contrast imaging settings.
نویسندگان
چکیده
AIMS Myocardial contrast perfusion echocardiography (MCE) allows simultaneous assessment of perfusion and function. However, low frame rate during MCE may reduce the viewer's ability to discern contractile dysfunction. This study sought to compare MCE and left ventricular opacification (LVO) settings with regard to wall motion abnormalities (WMA) at rest and during dobutamine stress echocardiography (DSE). METHODS AND RESULTS In 50 patients scheduled for coronary angiography and with poor baseline image quality, MCE and LVO were performed during DSE. Regional wall motion was assessed and inter-observer agreement was determined for each imaging modality. The endocardial border score index was similar for both modalities. The wall motion score index (WMSCI) at peak stress using MCE was well correlated with WMSCI obtained with LVO (r(2) = 0.9, P < 0.001). However, WMSCI at peak stress was underestimated by MCE (1.66 +/- 0.58 with DSE-LVO vs. 1.535 +/- 0.50 with DSE-MCE; P < 0.001). Inter-observer agreement on the presence of WMA was 0.65 for MCE and 0.67 for LVO at peak stress. CONCLUSION Myocardial contrast perfusion echocardiography provides equal endocardial border delineation compared with LVO modality. Although the inter-observer agreement is slightly higher with LVO compared with MCE, it is not significantly different with MCE at peak stress. Despite the similar improvement in endocardial border delineation, LVO settings allow the detection of more WMA than MCE at peak stress, leading to a significantly higher accuracy for the detection of ischaemia in patients suspected of coronary artery disease when only wall motion is taken into account.
منابع مشابه
Assessment of subendocardial function with myocardial contrast echocardiography.
The classical ischemic cascade anticipates perfusion disturbances to precede the development of wall motion abnormalities, but does not account for regional heterogeneity of both perfusion and function. In this issue of JACC: Cardiovascular Imaging, Xie et al. (1) examine the impact of subendocardial ischemia (identified using real-time myocardial contrast echocardiography [MCE]) on myocardial ...
متن کاملDobutamine MRI: A serious contender in pharmacological stress imaging?
Noninvasive techniques for assessing coronary artery disease (CAD) have improved dramatically over the past 20 years. This is particularly true with the advent of pharmacological stress testing in patients who are unable to exercise. Because myocardial perfusion and function are closely coupled, state-of-the-art stress imaging modalities have involved assessment of myocardial perfusion with rad...
متن کاملComputerized evaluation of echocardiographic stress tests in patients with poorly visualized endocardium using analysis of color-encoded contrast-enhanced images.
AIMS We hypothesized that real-time color encoding of contrast-enhanced images would allow objective detection of stress-induced wall motion abnormalities (WMA). METHODS We studied 117 patients with poorly visualized endocardium undergoing dobutamine stress tests. Color-encoded images (Philips, color kinesis) were obtained at rest and peak stress in four standard views during i.v. infusion of...
متن کاملSafety of dobutamine stress real-time myocardial contrast echocardiography.
OBJECTIVES The aim of this study was to determine the safety of dobutamine stress myocardial perfusion imaging (MPI) obtained by real-time contrast echocardiography (RTCE) and intravenous ultrasound contrast in a large cohort of patients with suspected coronary artery disease (CAD). BACKGROUND Despite the increasing number of studies showing the potential clinical utility of myocardial contra...
متن کاملA randomized cross-over study for evaluation of the effect of image optimization with contrast on the diagnostic accuracy of dobutamine echocardiography in coronary artery disease The OPTIMIZE Trial.
OBJECTIVES The purpose of this study was to evaluate whether the addition of a contrast agent to dobutamine stress echocardiography (DSE) improves its diagnostic accuracy for coronary artery disease (CAD) and to determine the effect of image quality on the diagnostic impact of contrast agent use in this setting. BACKGROUND Contrast agents can improve endocardial border definition. To date, ho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology
دوره 10 8 شماره
صفحات -
تاریخ انتشار 2009