Heart ablation using a planar rectangular high intensity ultrasound transducer and MRI guidance.

نویسندگان

  • Andreas Couppis
  • Christakis Damianou
  • Panayiotis Kyriacou
  • Cyril Lafon
  • Francoise Chavrier
  • Jean-Yves Chapelon
  • Alain Birer
چکیده

The aim of this study was to evaluate a flat rectangular (3×10mm(2)) MRI compatible transducer operating at 5MHz. The main task was to explore the feasibility of creating deep lesions in heart at a depth of at least 15mm. The size of thermal necrosis in heart tissue was estimated as a function of power and time using a simulation model. The system was then tested in an excised lamb heart. In this study, we were able to create lesions of 15mm deep with acoustic power of 6W for an exposure of approximately 1min. The contrast to noise ratio (CNR) between lesion and heart tissue was evaluated using fast spin echo (FSE). The CNR value was approximately 22 using T1W FSE. Maximum CNR was achieved with repetition time (TR) between 300 and 800ms. Using T2W FSE, the corresponding CNR was approximately 13 for the 14 in vivo experiments. The average lesion depth was 11.93mm with a standard deviation of 0.62mm. In vivo irradiation conditions were 6W for 60s. The size of the lesion in the other two dimensions was close to 3×10mm(2) (size of the transducer element).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

Laparoscopic High Intensity Focused Ultrasound: Application to Kidney Ablation

This work demonstrates the feasibility of using high intensity focused ultrasound (HIFU) for selective ablation of renal tissue through laparoscopic procedures. Two laparoscopic HIFU probe prototypes were developed and tested. Probe 1: It is a hand-held probe with no integrated ultrasound imaging capability. It consists of two focused rectangular HIFU piezoceramic crystals mounted on a stainles...

متن کامل

Evaluation of fast spin echo MRI sequence for an MRI guided high intensity focused ultrasound system for in vivo rabbit liver ablation

The effectiveness of magnetic resonance imaging (MRI) to monitor thermal lesions created by High Intensity Focused Ultrasound (HIFU) in rabbit liver in vivo is investigated. The MRI sequences of T1-weighted, and T2-weighted fast spin echo (FSE) were evaluated. The main goal in this paper was to find the range of repetition time (TR) and range of echo time (TE) which maximizes the contrast to no...

متن کامل

Simulation of the Thermal and Mechanical Effects of a Planar Rectangular High Intensity Ultrasound Transducer to Be Used for Destroying Atherosclerotic Plaque

The aim of this study is to perform a simulation study of the thermal and mechanical effects of a flat rectangular (3 × 10 mm), MRI compatible transducer operating at 5 MHz for the purpose of destroying atherosclerotic plaque. The simulation study focuses on measuring the plaque destruction (due to the thermal of mechanical mode of ultrasound) as a function of power, time, frequency, duty facto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasonics

دوره 52 7  شماره 

صفحات  -

تاریخ انتشار 2012