The effect of flattening filter free delivery on endothelial dose enhancement with gold nanoparticles.

نویسندگان

  • Alexandre Detappe
  • Panagiotis Tsiamas
  • Wilfred Ngwa
  • Piotr Zygmanski
  • Mike Makrigiorgos
  • Ross Berbeco
چکیده

PURPOSE The aim of this study is to quantify and to compare the dose enhancement factor from gold nanoparticles (AuNP) to tumor endothelial cells for different concentrations of AuNP, and clinical MV beam configurations. METHODS Tumor endothelial cells are modeled as slabs measuring 10 × 10 × 2 μm. A spherical AuNP is simulated on the surface of the endothelial cell, within the blood vessel. 6 MV photon beams with and without the flattening filter are investigated for different field sizes, depths in material and beam modulation. The incident photon energy spectra for each configuration is generated using EGSnrc. The dose enhancement in the tumor endothelial cell is found using an analytical calculation. The endothelial dose enhancement factor is defined to be the ratio of the dose deposited with and without AuNPs. RESULTS It is found that clinical beam parameters may be chosen to maximize the effect of gold nanoparticles during radiotherapy. This effect is further amplified ~20% by the removal of the flattening filter. Modulation of the clinical beam with the multileaf collimator tends to decrease the proportion of low energy photons, therefore providing less enhancement than the corresponding open field. CONCLUSIONS The results of this work predict a dose enhancement to tumor blood vessel endothelial cells using conventional therapeutic (MV) x-rays and quantify the relative change in enhancement with treatment depth and field size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode

Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis of basic dosimetric properties for a Saturne 43 Linac head to implement free flattening filter beams clinically. Material and Methods: Thi...

متن کامل

Study of Radiation Dose Enhancement to Capillary Endothelial Cells Due to the Presence of Heavy Metal Nanoparticles in Two Cell and Tumor Scales by Monte Carlo Method

Introduction: Recently, the use of various sensitizers has been used to increase photon-induced doses in brachytherapy. One of these cases is the addition of heavy metal nanoparticles such as gold in the target area, which increases the production of ionizing electrons by increasing the possibility of photoelectric effects, and increases the efficacy of the treatment. In this study, the target ...

متن کامل

Improvement of dose delivery with loading of tumor with gold nanoparticles in orthovoltage radiotherapy

Introduction: To enhance the dose to tumor, the use of high atomic number elements has been proposed. Objective: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic X-ray beams by considering homogeneous and inhomogeneous distributions of gold nanoparticles (GNPs)...

متن کامل

A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays

Background: To enhance the dose to tumor, the use of high atomic number elements has been proposed.Objective: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic X-ray beams by considering homogeneous and inhomogeneous distributions of gold nanoparticles (GNPs) in the tumor.Method...

متن کامل

Dose enhancement effect of gold nanoparticles on MAGICA polymer gel in mega voltage radiation therapy

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. Among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. Material and Methods: In this study...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2013