Long-term stable hydrogels for biorelevant dissolution testing of drug-eluting stents

نویسندگان

  • Beatrice Semmling
  • Stefan Nagel
  • Katrin Sternberg
  • Werner Weitschies
چکیده

Background: For the purpose of biorelevant dissolution testing hydrogels have recently been used to investigate release and distribution behavior of drugs released from specialized dosage forms such as drug-eluting stents. For stent testing using the vesselsimulating flow-through cell (vFTC) certain functional properties regarding life time of the used hydrogels such as hardening/ softening, degradation/erosion and swelling/shrinkage during the time period of dissolution testing are of highest interest. Methods: Hydrogels composed of alginate, agar, agarose, polyacrylamide (PAA) and poly(vinyl alcohol) (PVA) were prepared using physical and chemical cross-linking methods. To characterize the mechanical stability of the test specimens stress-strain curves were recorded by texture analysis before and after perfusion in the vFTC for 28 days and Young’s moduli were calculated. The surface morphology of the test specimens was examined using scanning electron microscopy. Water uptake upon incubation was determined. Results: Besides the previously established alginate gels, suitable hydrogels consisting of 2 wt% agar, 2 wt% agarose, 10 wt% PAA or 15 wt% PVA were identified. Comparison of stress-strain curves indicated a sample softening of reference as well as agar and a slight hardening of PVA whereas hardness of agarose and PAA remained unchanged. Young’s moduli of agarose and PAA were almost unaffected after 28 days of perfusion. Swelling of PAA by 18 wt% and shrinkage of PVA by 14 wt% was observed compared to agar and agarose whose water uptake was negligibly small. Conclusion: The hydrogels differ not only in their preparation procedure but also regarding their swelling properties, surface morphology and texture. Due to the ease of handling, mild gelling conditions, no swelling tendencies, elastic properties, and nearly unaffected texture after 28 days of perfusion compared to native test specimens, agarose gels are considered as the best choice for longterm testing using the vFTC.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biorelevant Dissolution Testing of Drug-Eluting Stents: Experiences with a Modified Flow-Through Cell Setup

In vitro dissolution testing of drug-eluting stents (DES) poses a special challenge in terms of apparatus design due to the very specialized local treatment of the vessel wall in the immediate vicinity of the blood flowing through the vessel and the stent lumen. A vessel-simulating flow-through cell was designed to emulate the placement of a DES in vivo and the flow through the lumen in a simpl...

متن کامل

Everolimus-eluting stents in interventional cardiology

Bare metal stents have a proven safety record, but limited long-term efficacy due to in-stent restenosis. First-generation drug-eluting stents successfully countered the restenosis rate, but were hampered by concerns about their long-term safety. Second generation drug-eluting stents have combined the low restenosis rate of the first generation with improved long-term safety. We review the evol...

متن کامل

Biorelevant Dissolution Methods and Their Applications in In Vitro- In Vivo Correlations for Oral Formulations

Dissolution tests that can predict the in vivo performance of drug products are usually called biorelevant dissolution tests. Biorelevant dissolution testing can be used to guide formulation development, to identify food effects on the dissolution and bioavailability of orally administered drugs, and to identify solubility limitations and stability issues. To develop a biorelevant dissolution t...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013