Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data

نویسندگان

  • John C Pickup
  • Suzanne C Freeman
  • Alex J Sutton
چکیده

OBJECTIVE To determine the clinical effectiveness of real time continuous glucose monitoring compared with self monitoring of blood glucose in type 1 diabetes. DESIGN Meta-analysis of randomised controlled trials. DATA SOURCES Cochrane database for randomised controlled trials, Ovid Medline, Embase, Google Scholar, lists of papers supplied by manufacturers of continuous glucose monitors, and cited literature in retrieved articles. Studies reviewed Randomised controlled trials of two or more months' duration in men and non-pregnant women with type 1 diabetes that compared real time continuous glucose monitoring with self monitoring of blood glucose and where insulin delivery was the same in both arms. Analysis Two step meta-analysis of individual patient data with the primary outcome of final glycated haemoglobin (HbA(1c)) percentage and area under the curve of hypoglycaemia (glucose concentration <3.9 mmol/L) during either treatment, followed by one step metaregression exploring patient level determinants of HbA(1c) and hypoglycaemia. RESULTS Six trials were identified, consisting of 449 patients randomised to continuous glucose monitoring and 443 to self monitoring of blood glucose. The overall mean difference in HbA(1c) for continuous glucose monitoring versus self monitoring of blood glucose was -0.30% (95% confidence interval -0.43% to -0.17%) (-3.0, -4.3 to -1.7 mmol/mol). A best fit regression model of determinants of final HbA(1c) showed that for every one day increase of sensor usage per week the effect of continuous glucose monitoring versus self monitoring of blood glucose increased by 0.150% (95% credibility interval -0.194% to -0.106%) (1.5, -1.9 to -1.1 mmol/mol) and every 1% (10 mmol/mol) increase in baseline HbA(1c) increased the effect by 0.126% (-0.257% to 0.0007%) (1.3, -2.6 to 0.0 mmol/mol). The model estimates that, for example, a patient using the sensor continuously would experience a reduction in HbA(1c) of about 0.9% (9 mmol/mol) when the baseline HbA(1c) is 10% (86 mmol/mol). The overall reduction in area under the curve of hypoglycaemia was -0.28 (-0.46 to -0.09), corresponding to a reduction in median exposure to hypoglycaemia of 23% for continuous glucose monitoring compared with self monitoring of blood glucose. In a best fit regression model, baseline area under the curve of hypoglycaemia was only weakly related to the effect of continuous glucose monitoring compared with self monitoring of blood glucose on hypoglycaemia outcome, and sensor usage was unrelated to hypoglycaemia at outcome. CONCLUSIONS Continuous glucose monitoring was associated with a significant reduction in HbA(1c) percentage, which was greatest in those with the highest HbA(1c) at baseline and who most frequently used the sensors. Exposure to hypoglycaemia was also reduced during continuous glucose monitoring. The most cost effective or appropriate use of continuous glucose monitoring is likely to be when targeted at people with type 1 diabetes who have continued poor control during intensified insulin therapy and who frequently use continuous glucose monitoring.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Meta-analysis of individual patient data in randomised trials of self monitoring of blood glucose in people with non-insulin treated type 2 diabetes.

OBJECTIVE To assess the effectiveness of self monitoring blood glucose levels in people with non-insulin treated type 2 diabetes compared with clinical management without self monitoring, and to explore the effects in specific patient groups. DESIGN Meta-analysis based on individual participant data. DATA SOURCES Medline, Embase, and a recent systematic review of trials on self monitoring o...

متن کامل

Glycaemic control with continuous subcutaneous insulin infusion compared with intensive insulin injections in patients with type 1 diabetes: meta-analysis of randomised controlled trials.

OBJECTIVE To compare glycaemic control and insulin dosage in people with type 1 diabetes treated by continuous subcutaneous insulin infusion (insulin infusion pump therapy) or optimised insulin injections. DESIGN Meta-analysis of 12 randomised controlled trials. PARTICIPANTS 301 people with type 1 diabetes allocated to insulin infusion and 299 allocated to insulin injections for between 2.5...

متن کامل

Continuous glucose monitoring systems for type 1 diabetes mellitus.

BACKGROUND Self-monitoring of blood glucose is essential to optimise glycaemic control in type 1 diabetes mellitus. Continuous glucose monitoring (CGM) systems measure interstitial fluid glucose levels to provide semi-continuous information about glucose levels, which identifies fluctuations that would not have been identified with conventional self-monitoring. Two types of CGM systems can be d...

متن کامل

Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetes

Diabetes mellitus is a chronic disease that necessitates continuing treatment and patient self-care education. Monitoring of blood glucose to near normal level without hypoglycemia becomes a challenge in the management of diabetes. Although self monitoring of blood glucose (SMBG) can provide daily monitoring of blood glucose level and help to adjust therapy, it cannot detect hypoglycemic unawar...

متن کامل

Changes in the glycaemic profiles of women with type 1 and type 2 diabetes during pregnancy

Aims – To examine the changes in glycaemic excursions which occur during pregnancy using continuous glucose monitoring and to compare patterns of glycaemia in pregnant women with type 1 and type 2 diabetes. Research design and methods – Observational data analysis from a prospective randomised study of continuous glucose monitoring in 57 women with pregestational type 1 (n=40) or type 2 diabete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 343  شماره 

صفحات  -

تاریخ انتشار 2011