Orbscan II-assisted intraocular lens power calculation for cataract surgery following myopic laser in situ keratomileusis (an American Ophthalmological Society thesis).

نویسنده

  • Henry Gelender
چکیده

PURPOSE This study tests the hypothesis that the keratometric value derived from Orbscan II mean power maps, when used in an intraocular lens (IOL) calculation formula, at a specific measurement zone, will accurately determine the power of an IOL for planned cataract surgery in patients who have undergone prior myopic laser-assisted in situ keratomileusis (LASIK). METHODS This is a two-part study conducted in a referral practice. Experiment 1 is a prospective study of 59 eyes of 30 patients undergoing LASIK. The change in Orbscan mean power maps at five central zones (1.0, 1.5, 2.0, 2.5, and 3.0 mm) was compared with the refractive change from LASIK to determine the optimum Orbscan correlation zone. In Experiment 2, the power of the LASIK-altered cornea was measured by Orbscan and applied to IOL calculations for 17 eyes of 13 patients undergoing cataract surgery. RESULTS In Experiment 1, analysis at the Orbscan 1.0-mm measurement zone demonstrated overestimation of the refractive change, whereas the 2.5-mm and 3.0-mm zones demonstrated underestimation. The 1.5-mm and 2.0-mm zones best approximated the net refractive change following LASIK. In Experiment 2, the Orbscan power at 1.5 mm was selected for IOL calculations to minimize undercorrections. The refractive error following cataract surgery ranged from -0.75 to +0.90 diopters (average, +0.05 diopters). Eight eyes were overcorrected (average, -0.52 diopters) and nine eyes were undercorrected (average, +0.54 diopters). CONCLUSIONS The 1.5-mm Orbscan II zone measures the effective power of the LASIK-altered cornea. When applied to an IOL calculation formula, it accurately predicts the IOL power for planned cataract surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of intraocular lens power calculation methods in eyes that have undergone laser-assisted in-situ keratomileusis.

PURPOSE To compare methods of calculating intraocular lens (IOL) power for cataract surgery in eyes that have undergone myopic laser-assisted in-situ keratomileusis (LASIK). METHODS Eleven eyes of eight patients who had previously undergone myopic LASIK (amount of LASIK correction, -5.50 +/- 2.61 D (SD); range, -8.78 to -2.38 D) and subsequently phacoemulsification with implantation of the SA...

متن کامل

No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis.

PURPOSE To prospectively evaluate the no-history method for intraocular lens (IOL) power calculation in 15 cataractous eyes that had previous myopic laser in situ keratomileusis (LASIK) and for which the pre-LASIK K-readings were not available. SETTING Private practice, Lynwood, California, USA. METHODS The predicted IOL power was calculated in each case. Also calculated were the mean arith...

متن کامل

Calculation of intraocular lens power using Orbscan II quantitative area topography after corneal refractive surgery.

PURPOSE To present the prospective application of the Orbscan II central 2-mm total-mean corneal power obtained by quantitative area topography in intraocular lens (IOL) calculation after refractive surgery. METHODS Calculated and achieved refraction and the difference between them were studied in 77 eyes of 61 patients with previous radial keratotomy (RK), RK and additional surgeries, myopic...

متن کامل

Optical coherence tomography-based corneal power measurement and intraocular lens power calculation following laser vision correction (an American Ophthalmological Society thesis).

PURPOSE To use optical coherence tomography (OCT) to measure corneal power and improve the selection of intraocular lens (IOL) power in cataract surgeries after laser vision correction. METHODS Patients with previous myopic laser vision corrections were enrolled in this prospective study from two eye centers. Corneal thickness and power were measured by Fourier-domain OCT. Axial length, anter...

متن کامل

Comparison of intraocular lens power calculation methods after myopic laser refractive surgery without previous refractive surgery data.

PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation methods for post-myopic excimer laser surgery patients without previous refractive surgery data using the Holladay IOL Consultant Program and the American Society of Cataract and Refractive Surgery (ASCRS) IOL Power Calculator. SETTING Wang Vision Cataract and LASIK Center, Nashville, Tennessee, USA. DESIGN Case ser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transactions of the American Ophthalmological Society

دوره 104  شماره 

صفحات  -

تاریخ انتشار 2006