Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging.

نویسندگان

  • Daniel S Berman
  • Xingping Kang
  • Balaji Tamarappoo
  • Arik Wolak
  • Sean W Hayes
  • Ryo Nakazato
  • Louise E J Thomson
  • Faith Kite
  • Ishac Cohen
  • Piotr J Slomka
  • Andrew J Einstein
  • John D Friedman
چکیده

OBJECTIVES Our purpose was to describe a novel, rapid stress thallium-201 (Tl-201)/rest technetium-99m (Tc-99m) agent myocardial perfusion imaging (MPI) protocol (Tl/Tc) with a high-speed MPI scanner and to compare this protocol with a standard rest/stress Tc-99m agent protocol (Tc/Tc) with respect to image quality and radiation dosimetry. BACKGROUND Recent advances in gamma camera technology have provided opportunity for improved SPECT MPI protocols. A rapid Tl/Tc protocol that could improve image information while maintaining a low radiation burden for the patient would be desirable. METHODS We compared high-speed SPECT MPI studies in 374 consecutive patients undergoing exercise or pharmacologic Tl/Tc protocol to those of 262 patients undergoing rest/stress Tc/Tc protocol. RESULTS Tl/Tc imaging was accomplished in <20 min. Overall image quality was good to excellent in 96% and 98% of patients with the Tl/Tc and the Tc/Tc protocols, respectively (p = ns). Beginning rest imaging within 2 min after rest injection with the Tl/Tc protocol did not result in reduced confidence in image interpretation. Early rest Tc images of the Tl/Tc protocol showed less extracardiac activity than was observed on standard rest imaging used in the Tc/Tc protocol (84% vs. 61%), respectively (p < 0.01). The normalcy rate was high in both groups (100% vs. 92%). Radiation burden was similar between the Tl/Tc and Tc/Tc protocols. CONCLUSIONS A rapid stress Tl-201/rest Tc-99m protocol for use with high-speed SPECT MPI has image quality and radiation dosimetry similar to those observed with a conventional rest/stress Tc-99m protocol. The Tl/Tc protocol offers promise as an efficient and relatively low radiation dose method, in which the superior qualities of Tl-201 for stress imaging and of the Tc-99m agents for rest imaging can be preserved. The findings also suggest that with rapid imaging rest MPI immediately after Tc-99m agent injection may be superior to standard delayed image initiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2...

متن کامل

0054: Validation of stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging against fractional flow reserve for the detection of the extent of ischemia

0430 Table LA Emptying fraction CMR Maximal LAVICMR LGE <17.5% >17.5% p <44 ml/m >44 ml/m p – + p Mitral E/A ratio 2.98±1.82 0.89±0.28 <0.001 1.51±1.4 2.22±1.8 0.2 1.35±1.3 2.43±1.9 0.055 DT TTE (ms) 158±45 217±56 <0.001 190±65 183±53 0.7 219±51 145 ±39 <0.001 Lateral E/e’ 16.9±6.8 12.1±6.4 <0.04 14±7 14.8±7 0.8 13.6±7.4 15.7±6.4 0.4 GLS –10.1±3.1 –17.3±3.7 <0.001 –14.2±5.3 –12.7±4.6 0.4 –16.5±...

متن کامل

Quantitative rest technetium-99m tetrofosmin imaging in predicting functional recovery after revascularization: comparison with rest-redistribution thallium-201.

OBJECTIVES This study was undertaken to 1) compare the regional myocardial tracer distributions between rest technetium (Tc)-99m tetrofosmin and rest-redistribution thallium (Tl)-201 images in patients with coronary artery disease and left ventricular dysfunction; and 2) assess the comparative values of these agents for predicting functional recovery after revascularization. BACKGROUND Tc-99m...

متن کامل

Diagnostic value of a new myocardial perfusion agent, teboroxime (SO 30,217), utilizing a rapid planar imaging protocol: preliminary results.

Technetium-99m-labeled agents have advantages over thallium-201 in terms of photon statistics, cost and clinical availability. They have been suggested as an alternative to thallium for myocardial perfusion imaging. Teboroxime is a new boronic acid adduct of technetium dioxime (BATO) compound that demonstrates favorable characteristics in preliminary studies. With use of a novel (seated) patien...

متن کامل

New Technetium-Labeled Myocardial Perfusion Agents

Radionuclide myocardial perfusion imaging in conjunction with exercise or pharmacologic stress testing is an established technique for diagnosing and assessing the severity of coronary artery disease (1 ). Currently TI is the most widely used radiopharmaceutical for myocardial perfusion imaging. Thallium-201, however, has disadvantages such as low photopeak energy (69-83 keV), which can cause d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 2 3  شماره 

صفحات  -

تاریخ انتشار 2009