Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography

نویسندگان

  • René M. Werkmeister
  • Stefan Palkovits
  • Reinhard Told
  • Martin Gröschl
  • Rainer A. Leitgeb
  • Gerhard Garhöfer
  • Leopold Schmetterer
چکیده

PURPOSE There is a long-standing interest in the study of retinal blood flow in humans. In the recent years techniques have been established to measure retinal perfusion based on optical coherence tomography (OCT). In the present study we used a technique called dual-beam bidirectional Doppler Fourier-domain optical coherence tomography (FD-OCT) to characterize the effects of 100% oxygen breathing on retinal blood flow. These data were compared to data obtained with a laser Doppler velocimeter (LDV). METHODS 10 healthy subjects were studied on 2 study days. On one study day the effect of 100% oxygen breathing on retinal blood velocities was studied using dual-beam bidirectional Doppler FD-OCT. On the second study day the effect of 100% oxygen breathing on retinal blood velocities was assessed by laser Doppler velocimetry (LDV). Retinal vessel diameters were measured on both study days using a commercially available Dynamic Vessel Analyzer. Retinal blood flow was calculated based on retinal vessel diameters and red blood cell velocity. RESULTS As expected, breathing of pure oxygen induced a pronounced reduction in retinal vessel diameters, retinal blood velocities and retinal blood flow on both study days (p<0.001). Blood velocity data correlated well between the two methods applied under both baseline as well as under hyperoxic conditions (r = 0.98 and r = 0.75, respectively). Data as obtained with OCT were, however, slightly higher. CONCLUSION A good correlation was found between red blood cell velocity as measured with dual-beam bidirectional Doppler FD-OCT and red blood cell velocity assessed by the laser Doppler method. Dual-beam bidirectional Doppler FD-OCT is a promising approach for studying retinal blood velocities in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography.

There is considerable interest in new methods for the assessment of retinal blood flow for the diagnosis of eye diseases. We present in vivo normal human volumetric retinal flow measurement using Fourier domain Doppler optical coherence tomography. We used a dual-plane scanning pattern to determine the angle between the blood flow and the scanning beam in order to measure total flow velocity. V...

متن کامل

Retinal blood flow measurement with ultrahigh-speed swept-source / Fourier domain optical coherence tomography

Doppler OCT is a functional extension of OCT that provides information on flow in biological tissues. We present a novel approach for total retinal blood flow assessment using ultrahigh speed Doppler OCT. A swept source / Fourier domain OCT system at 1050 nm was used for 3D imaging of the human retina. The high axial scan rate of 200 kHz allowed measuring the high flow velocities in the central...

متن کامل

Retinal Blood Flow Response to Hyperoxia Measured With En Face Doppler Optical Coherence Tomography

PURPOSE To use multiplane en face Doppler optical coherence tomography (OCT) to measure the change in total retinal blood flow (TRBF) in response to hyperoxia. METHODS One eye of each healthy human participant (n = 8) was scanned with a commercial high-speed (70-kHz) spectral OCT system. Three repeated scans were captured at baseline and after 10 minutes of oxygen (hyperoxia) by open nasal ma...

متن کامل

Doppler optical coherence tomography of retinal circulation.

Noncontact retinal blood flow measurements are performed with a Fourier domain optical coherence tomography (OCT) system using a circumpapillary double circular scan (CDCS) that scans around the optic nerve head at 3.40 mm and 3.75 mm diameters. The double concentric circles are performed 6 times consecutively over 2 sec. The CDCS scan is saved with Doppler shift information from which flow can...

متن کامل

Assessment of total retinal blood flow using Doppler Fourier Domain Optical Coherence Tomography during systemic hypercapnia and hypocapnia

The purpose of this study was to investigate changes in total retinal blood flow (RBF) using Doppler Fourier Domain Optical Coherence Tomography (Doppler FD-OCT) in response to the manipulation of systemic partial pressure of CO2 (PETCO2). Double circular Doppler blood flow scans were captured in nine healthy individuals (mean age ± standard deviation: 27.1 ± 4.1, six males) using the RTVue(™) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012