Accuracy of several implant bite registration techniques: an in-vitro pilot study
نویسندگان
چکیده
PURPOSE This study evaluated the accuracies of different bite registration techniques for implant-fixed prostheses using three dimensional file analysis. MATERIALS AND METHODS Implant fixtures were placed on the mandibular right second premolar, and the first and second molar in a polyurethane model. Aluwax (A), Pattern Resin (P), and Blu-Mousse (B) were used as the bite registration materials on the healing abutments (H) or temporary abutments (T). The groups were classified into HA, HP, HB, TA, TP, and TB according to each combination. The group using the bite impression coping was the BC group; impression taking and bite registration were performed simultaneously. After impression and bite taking, the scan bodies were connected to the lab analogs of the casts. These casts were scanned using a model scanner. The distances between two reference points in three-dimensional files were measured in each group. One-way ANOVA and Duncan's test were used at the 5% significance level. RESULTS The smallest distance discrepancy was observed in the TB group using the temporary abutments. The Blu-Mousse and HP groups showed the largest distance discrepancy. The TB and BC groups showed a lower distance discrepancy than the HP group (P=.001), and there was no significant difference between the groups using the temporary abutments and healing abutments (P>.05). CONCLUSION Although this study has limitations as an in-vitro investigation, the groups using the temporary abutments to hold the Blu-Mousse record and bite impression coping showed greater accuracy than the group using the healing abutments to hold the pattern resin record.
منابع مشابه
Evaluation of accuracy of complete-arch multiple-unit abutment-level dental implant impressions using different impression and splinting materials.
PURPOSE This in vitro study evaluated the accuracy of multiple-unit dental implant casts obtained from splinted or nonsplinted direct impression techniques using various splinting materials by comparing the casts to the reference models. The effect of two different impression materials on the accuracy of the implant casts was also evaluated for abutment-level impressions. MATERIALS AND METHOD...
متن کاملPrinciples of Neuronavigation
Background and Aim: Numerous efforts over the past century have been performed. Various innovation techniques are increasingly gaining attention and gradually established the foundation of recent significant developments in the world of neurosurgery, among which varied stereotactic neuro-navigation designs and other novel emerging systems are being quotidian developed. This narrative review ai...
متن کاملClinical Determination of Target Registration Error of an Image- Guided Otologic Surgical System using Patients with Bone-Anchored Hearing Aids
Image guidance in otologic surgery has been thwarted by the need for a non-invasive fiducial system with target registration error (TRE) at the inner ear below 1.5mm. We previously presented a fiducial frame for this purpose that attaches to the upper dentition via patient-specific bite blocks and demonstrated a TRE of 0.73mm (±0.23mm) on cadaveric skulls. In that study, TRE measurement depende...
متن کاملبررسی مقایسهای دو سیستم Cone Beam CT به لحاظ دقت اندازهگیری خطی محلهای قراردهی ایمپلنت در مندیبل بهصورت In Vitro
Background and Objective: There are critical areas in the mandible that should be considered during implant placement such as inferior alveolar canal, mental foramen, and the root of the adjacent tooth. Two-dimensional images obtained from periapical, panoramic, and conventional tomography are considered in the evaluation of implant placement and bone quality. Cone-beam computed tomography (CBC...
متن کاملDimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study
Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...
متن کامل