An assessment of the relative safety of dental x-ray equipment.
نویسندگان
چکیده
Concern among patients, often prompted by medical practitioners, regarding the harmful effects of radiation caused by dental x-ray procedures, has caused several patients of the dental school of the University of Pretoria to refuse dental radiographic procedures. Buch and Fensham in a previous article demonstrated that radiation doses to the eyes and thyroid resulting from a single pantomogram constituted less than 10% of that which would be imparted by a transatlantic flight in terms of added natural background radiation. The authors in this study investigated doses to the same organs resulting from a full-mouth periapical series first using films and then digital imaging. Doses to the uterus resulting from these same examinations as well as from a pantomogram were also determined both with and without the use of a lead apron. Doses to the eye from a full-mouth examination using film compared favourably with those for a panoramic examination, but were much reduced when digital imaging techniques were employed. Doses to the uterus were small (equivalent to half a day of background radiation) for both a full-mouth examination using digital imaging, as well as for a pantomogram. However, from the results it would appear that there is little difference in the dose of scatter radiation to the uterus from a full-mouth examination whether or not a lead apron is used. The use of a lead apron for a pantomogram significantly reduces the dose to the uterus.
منابع مشابه
Performance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea
Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every 3 years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment i...
متن کاملQuality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran
Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...
متن کاملEvaluation of X-ray protective shielding used in dental offices in Kerman, Iran, in 2014
BACKGROUND AND AIM: Protective equipment, such as lead aprons and thyroid shields, is effective in reducing patient radiation. This study was conducted for evaluation the use of thyroid shields and lead aprons in dental offices, in Kerman, Iran, in June 2014.METHODS: In this descriptive-analytical study, 106 dental offices with active X-ray machines were evaluated in Kerman. The information was...
متن کاملEvaluation of X-Ray Absorption by Ointment Containing Bismuth Oxide Nanoparticles in Radiology Staff
Introduction: The effects of X-rays on carcinogens have been proven in recent years. Today, lead is used in many devices such as lead covers, thyroid protectors to protect the body against x-rays. But this equipment contains many disadvantages such as, Toxicity, High weight and Lack of flexibility. Today, newer methods, such as semi-solid skin care products (cream, ointment), a...
متن کاملNovel Semisolid Design Based on Bismuth Oxide (Bi2O3) nanoparticles for radiation protection
Objective(S): The dangerous effects of X-ray have been elucidated by scientific studies in occupational health hygiene. X-ray protective like an apron, thyroid shield and gloves have been made of lead (Pb) to protect against X-ray. However, such equipment makes a lot of safety and health problems such as toxicity, weight, inflexibility and troubles usage in a physician. To ove...
متن کاملAn Enumeration Survey on Diagnostic X-Ray Generators and Essential Safety Parameters in Mizoram, India
Introduction: Best radiography practice involves operational optimal machine performance, delivering cost-effective healthcare services under appropriate safety conditions for workers and the public. The present study aimed to investigate the safety status of diagnostic X-ray installations in Mizoram, India. Material and Methods: Lineari...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- SADJ : journal of the South African Dental Association = tydskrif van die Suid-Afrikaanse Tandheelkundige Vereniging
دوره 64 8 شماره
صفحات -
تاریخ انتشار 2009