The aim of the present study was to analyse the role of continuous positive airway pressure (CPAP) treatment in patients with difficult-to-control hypertension (DC-HT) and sleep apnoea. An Autoset (ResMed, Sydney, Australia) study was performed in 60 patients diagnosed with DC-HT based on two 24-h ambulatory blood pressure monitorisation (ABPM) studies. CPAP was offered to patients with an apnoea/hypopnoea index (AHI) > or =15 events.h(-1). After 3 months of treatment, repeat ABPM was performed to evaluate the effect of CPAP upon the blood pressure values. A total of 39 (65%) patients received CPAP treatment, but only 33 completed the study. The mean+/-sd systolic and diastolic blood pressures (SBP and DBP, respectively) were 154.8+/-14 and 90+/-8.8 mmHg. Patients had a mean+/-sd AHI of 37.7+/-18.2 events.h(-1). Only three patients presented a dipper nocturnal pressure pattern. CPAP treatment significantly reduced SBP (-5.2 mmHg), and particularly the nocturnal values (-6.1 mmHg), but not DBP. Considering only those patients who tolerated CPAP, the decrease in SBP was greater (-7.3 mmHg). Furthermore, CPAP treatment significantly increased the percentage of patients who recovered the dipper pattern (three (9.1%) out of 33 versus 12 (36.4%) out of 33). Continuous positive airway pressure treatment significantly reduces systolic blood pressure, particularly at night, and normalises the nocturnal pressure pattern in patients with difficult-to-control hypertension and sleep apnoea.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of continuous positive airway pressure treatment on clinic and ambulatory blood pressures in patients with obstructive sleep apnea and resistant hypertension: a randomized controlled trial.

The effect of continuous positive airway pressure (CPAP) on blood pressures (BPs) in patients with resistant hypertension and obstructive sleep apnea is not established. We aimed to evaluate it in a randomized controlled clinical trial, with blinded assessment of outcomes. Four hundred thirty-four resistant hypertensive patients were screened and 117 patients with moderate/severe obstructive sl...

متن کامل

The Effect of Body Position on Pain Due to Nasal Continuous Positive Airway Pressure (CPAP) in Premature Neonates: A Cross-Over Clinical Trial Study

Background The most common cause of admission to neonatal intensive care units (NICU) is respiratory distress syndrome. One of the respiratory assistance methods is using nasal continuous positive airway pressure (CPAP). Regarding the importance of pain control which is one of the major priorities in neonatal nursing care, this study aimed to evaluate the effect of body position on pain due to ...

متن کامل

Effect of nocturnal nasal continuous positive airway pressure on blood pressure in obstructive sleep apnea.

Obstructive sleep apnea (OSA) is a very common risk factor for hypertension, and continuous positive airway pressure (CPAP) has been widely used to treat OSA. We conducted a meta-analysis of randomized, controlled trials to evaluate the effects of CPAP on blood pressure, reported as either a primary or secondary end point, among patients with OSA. Studies were retrieved by searching Medline (Ja...

متن کامل

Effect of Bubble and Ventilator-derived Continuous Positive Airway Pressure on the Management of Respiratory Distress Syndrome in Premature Neonates

Background: In this study, we aimed to compare ventilator-derived and bubble continuous positive airway pressure (CPAP) in neonates with respiratory distress syndrome admitted to Neonatal Intensive Care Unit of Vali-e-Asr Hospital, Birjand, Iran, in 2014. Methods: This cohort study was conducted among 68 patients assigned into two groups. The neonates in group A (32 infants) were treated with b...

متن کامل

Effect of continuous positive airway pressure on blood pressure in hypertensive patients with coronary artery bypass grafting and obstructive sleep apnea.

BACKGROUND Previous studies have documented that obstructive sleep apnea (OSA) increases the incidence of hypertension, respiratory failure and unexpected post-operative deaths during night in coronary artery bypass grafting (CABG) patients. We hypothesized that continuous positive airway pressure (CPAP) reduces blood pressure in these patients. METHODS We conducted a prospective, controlled ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 2007