Inversion Algorithm by Integral Type Reconstruction Formula for Magnetic Resonance Elastography
نویسندگان
چکیده
M. Suga, H. Miura, H. Fujiwara, T. Yamamoto, T. Tanaka, Q. YU, K. Arai, J. P. GONG, G. Nakamura, H. Ikehira, and T. Obata Graduate School of Technology, Chiba University, Chiba, Chiba, Japan, Molecular Imaging Center, National Institute of Radiological Sciences, Chiba, Chiba, Japan, Graduate School of Informatics, Kyoto University, Faculty of Engineering, Gunma University, Graduate School of Science, Hokkaido University
منابع مشابه
Numerical simulations of magnetic resonance elastography using finite element analysis with a linear heterogeneous viscoelastic model
Abstract Magnetic resonance elastography (MRE) is a technique to identify the viscoelastic moduli of biological tissues by solving the inverse problem from the displacement field of viscoelastic wave propagation in a tissue measured by MRI. Because finite element analysis (FEA) of MRE evaluates not only the viscoelastic model for a tissue but also the efficiency of the inversion algorithm, we d...
متن کاملA Dual-Stage Reconstruction Algorithm for Magnetic Resonance Elastography
METHODS Spin echo encoded, steady-state harmonic motion data was collected from a cylindrical, gelatine phantom containing multiple inclusions in order to test a dual-stage Magnetic Resonance Elastography (MRE) reconstruction approach. This reconstruction method uses a viscoelastic shear modulus distribution calculated from derivatives of filtered displacement values as an initial guess for an ...
متن کاملNon-identifiability of the Rayleigh damping material model in magnetic resonance elastography.
Magnetic Resonance Elastography (MRE) is an emerging imaging modality for quantifying soft tissue elasticity deduced from displacement measurements within the tissue obtained by phase sensitive Magnetic Resonance Imaging (MRI) techniques. MRE has potential to detect a range of pathologies, diseases and cancer formations, especially tumors. The mechanical model commonly used in MRE is linear vis...
متن کاملMultifrequency inversion in magnetic resonance elastography.
Time-harmonic shear wave elastography is capable of measuring viscoelastic parameters in living tissue. However, finite tissue boundaries and waveguide effects give rise to wave interferences which are not accounted for by standard elasticity reconstruction methods. Furthermore, the viscoelasticity of tissue causes dispersion of the complex shear modulus, rendering the recovered moduli frequenc...
متن کاملImaging of Rayleigh damping properties of the in vivo brain using parametric Magnetic Resonance Elastography
The three parameter Rayleigh damping (RD) model applied to time-harmonic Magnetic Resonance Elastography (MRE) has potential to better characterise fluid-saturated tissue systems. However, it is not uniquely identifiable at a single frequency. One solution to this problem involves simultaneous inverse problem solution of multiple input frequencies over a broad range. As data is often limited, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008