Integral and shell-MIP display algorithms in MR and CT three-dimensional models of the brain surface.

نویسندگان

  • S O Casey
  • D Rubinstein
  • K O Lillehei
  • R A Alberico
  • R R Ozsvath
  • A G Cajade-Law
  • B E Weprin
  • E Michel
  • C L Truwit
چکیده

BACKGROUND AND PURPOSE Our purpose was to demonstrate the use of integral and shell maximum intensity projection (shell-MIP) display algorithms in the 3-D CT and MR depiction of cerebral gyral and surface venous anatomy and disorders. These new algorithms are compared against MIP and shaded-surface-display (SSD) algorithms. METHODS Integral and shell-MIP displays were generated from a specified number of proximal surface voxel layers in a 3-D model. Algorithmic models were compared on nine contrast-enhanced spoiled gradient-recalled acquisition in a steady state (SPGR) MR venograms for brain surface anatomic identification and detail. Seven CT venograms were compared for conspicuity of filling defects. Twelve contrast-enhanced preoperative planning 3-D MR models were rated for neurosurgical utility. RESULTS A shell-MIP score of 7.00 and an integral score of 6.78 represented the highest mean subjective MR gyral quality (1-10 scale) followed by an SSD score of 3.89 and an MIP score of 1.06. Mean confidence scores for MR central sulcus identification (1-10 scale) were shell-MIP, 7.67; integral, 7.00; SSD, 3.22; and MIP, 1.00. Mean superficial venous quality MR ratings (1-10 scale) were shell-MIP, 8.22; MIP, 7.39; integral, 7.00; and SSD, 3.72. The mean number of cortical veins draining into each side of the superior sagittal sinus on MR was as follows: MIP, 6.19; integral, 6.06; shell-MIP, 5.94; and SSD, 3.81. Mean confidence scores for filling defect identification on CT venograms (1-5 scale) revealed a shell-MIP score of 4.36 and an integral score of 4.29 to be superior to a MIP score of 3.00. In selected cases, 3-D presurgical planning, prior to tumor resection, was clinically useful. CONCLUSION Integral and shell-MIP are useful 3-D display algorithms for simultaneous display of superficial cerebral veins and gyri on MR images and of thrombosis on CT venograms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fusion and display of 3D SPECT and MR images registered by a surface fitting method

Since 3D medical images such as SPECT and MRI are taken under different patients positioning and imaging parameters, interpretation of them, as reconstructed originally, does not provide an easy and accurate understanding of similarities and differences between them. The problem becomes more crucial where a clinician would like to map accurately region of interest from one study to the ot...

متن کامل

Generating the synthetic CT (sCT) and synthetic MR (sMR: sT1w/sT2w) images of the brain using atlas based method

Introduction: Radiation therapy planning (RTP) is one of the clinical applications in which both CT scan and MRI are used. MR and CT images are applied to determine the target volume and calculation of dose distribution, respectively. In addition, using two imaging modalities increases the department workload and cost. In this study, an algorithm was presented to create synthet...

متن کامل

Generating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method

Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...

متن کامل

Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching

Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 19 8  شماره 

صفحات  -

تاریخ انتشار 1998