Extent of Electrocardiographic Ischemic Changes and Duration of Inflation With Standard and Autoperfusion Angioplasty SRI PBC SR
نویسندگان
چکیده
An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between two inflations by standard angioplasty catheters. Chest pain score, 12-lead electrocardiogram, heart rate, and mean aortic pressure were recorded before each inflation and at 1-minute intervals after inflation. Inflation duration during autoperfusion angioplasty (513+± 303 seconds) was longer than for the pre(107+±-55 seconds, p=0.0004) and post(139+± 71 seconds, p=0.0006) standard dilatations. The maximum ST-segment elevation and depression in any lead during autoperfusion angioplasty (0.3 0.5 and 0.6 0.8 mm) was significantly less than for the pre(2.4± 1.7 mm, p=0.002 and 2.2± 1.3 mm, p=0.0004) or post(1.9 + 1.3 mm, p= 0.002 and 1.6±+1.3 mm, p= 0.018) standard dilatations at the same point in time. Maximal chest pain score during autoperfusion (3.2-+ 3.5) was lower than for the pre(6.1 2. 1, p=0.003) but not the post(5.2 3.1, p=0.07) standard angioplasty. All 11 patients underwent successful, uncomplicated procedures. We conclude that this autoperfusion catheter significantly reduces ischemic symptoms and signs during coronary angioplasty, allowing prolonged periods of balloon inflation. (Circulation 1988;78:1128-1134)
منابع مشابه
Extent of Electrocardiographic Ischemic Changes and Duration of Inflation With Standard and Autoperfusion Angioplasty SRI PBC SR 2 ST
An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between ...
متن کاملMyocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans.
An autoperfusion balloon catheter was developed to allow passive myocardial perfusion during inflation through a central lumen and multiple side holes in the shaft proximal and distal to the balloon. We report its safety and efficacy in 11 patients undergoing elective angioplasty to a single coronary lesion. Each lesion was dilated three times with the autoperfusion inflation bracketed between ...
متن کاملPreservation of distal coronary perfusion during prolonged balloon inflation with an autoperfusion angioplasty catheter.
A newly designed balloon coronary angioplasty catheter that allows passive antegrade blood flow during balloon inflation (autoperfusion catheter) was compared with a standard balloon coronary angioplasty catheter. In a randomized sequence, inflations were performed for 3 min in the left circumflex coronary artery of 12 dogs with the standard catheter followed by the autoperfusion catheter or vi...
متن کاملElectrocardiographic parameters of Markhoz goat using base apex lead and six standard limb leads
Electrocardiographic study of 50 healthy Markhoz goats ranging from less than 1 to more than 3 years inage was carried out. The heart rate varied from 99 to 123 beats/min with a mean of 110 beats/min. There wasa significant difference between the heart rate of goats in 3 age groups (PT waves and QT interval in base apex lead, QRS wave in lead I, P-R and PQ interval in aVF lead were higherand du...
متن کاملIschemia and reperfusion during intermittent coronary occlusion in man. Studies of electrocardiographic changes and CPK release.
The course of 357 balloon inflations performed during 38 angioplasties for single-vessel coronary artery disease was prospectively studied using continuous ECG recording. Ischemic ECG changes appeared during 91 percent of the inflations at a mean of 20 +/- 8 seconds after inflation and resolved in 97 percent of those at a mean of 11 +/- 5 seconds after deflation. Elevation of the plasma CPK lev...