Longitudinal Heart Failure Medication Use and Adherence Following Left Ventricular Assist Device Implantation in Privately Insured Patients
نویسندگان
چکیده
BACKGROUND There are few data describing the longitudinal use of and adherence to heart failure medications following left ventricular assist device (LVAD) implantation. METHODS AND RESULTS Using a large US commercial insurance database, patients who received an LVAD (International Classification of Diseases, 9th Revision, Clinical Modification code 37.66) and survived to hospital discharge without heart transplantation between January 1, 2006, and March 31, 2015, were identified. Heart failure medication use from 3 months before 1-year post-LVAD was examined using linked pharmacy claims. Differences in the proportion of patients taking heart failure medications post LVAD compared with pre LVAD were examined using McNemar test. Predictors of post-LVAD medication use and poor medication adherence (proportion of days covered <0.8) were identified via logistic regression. Among 362 patients (mean age, 57.4 years; 75.1% men), compared with pre LVAD, the proportion of patients taking anticoagulants and antiarrhythmics following LVAD increased; mineralocorticoid receptor antagonists, thiazide diuretics, and digoxin decreased; and β-blockers, angiotensin-converting enzyme inhibitors/angiotensin receptor blockers, and loop diuretics did not change. Pre-LVAD medication use was associated with post-LVAD use across all medication classes. The proportion of patients with poor medication adherence was 28.8%, 39.0%, and 36.0% for β-blockers, angiotensin-converting enzyme inhibitors/angiotensin receptor blockers, and anticoagulants, respectively. Many patients with poor adherence completely discontinued use of the medication. CONCLUSIONS Neurohormonal antagonist use after LVAD was inconsistent, perhaps reflecting uncertainty of therapeutic benefit in this population. Medication adherence post-LVAD was poor in many patients. Further work is needed to delineate the reasons for nonadherence after LVAD.
منابع مشابه
Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملThe Relationship Between Medication Adherence and Coping Skills in Patients With Heart Failure
Introduction: Medication adherence is essential to improve outcomes emanated from the disease. The increase in the complexity of the medical regimens causes poor adherence in patients with heart failure; also, the progressive nature of Heart Failure (HF) and its complicated drug regimens are mostly stressful. This study has been conducted on the HF patients at the heart hospital of Kermanshah c...
متن کاملApical pseudoaneurysm following continuous flow left ventricular assist device placement.
The HeartMate II continuous flow left ventricular assist device (LVAD) (Thoratec Inc) provides circulatory support for patients with medically refractory systolic heart failure as both a bridge to transplantation and destination therapy. Although left ventricular apical pseudoaneurysm has rarely been reported with first-generation pulsatile flow LVADs, this has not been previously reported with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2017