Productivity metrics in dynamic LCA for whole buildings: Using a post-occupancy evaluation of energy and indoor environmental quality tradeoffs
نویسندگان
چکیده
The IEQ þ DLCA framework, which integrates indoor environmental quality (IEQ) and dynamic life cycle assessment (DLCA) at the whole-building level, was revised and expanded to consider non-chemical health impacts and productivity/performance impacts. The complete framework was evaluated for a case study of a LEED gold rated university building, supplementedwith a post-occupancy evaluation (POE) designed to elicit qualitative feedback on IEQ and productivity impacts specific to the building. Most nonchemical health impacts (e.g. sick building syndrome (SBS), asthma) were not able to be included in the framework, due to potential overlaps with chemical-specific impacts already included in LCA. However, productivity impacts were able to be included in the framework for the purpose of comparing different design and operational choices for a given building. Occupants were also asked to evaluate the anticipated effects on their individual productivity due to IEQ changes associated with hypothetical energy-saving strategies. Results of the POE showed occupants were generally satisfied with IEQ, and considered that increasing summer cooling temperature set points would enhance productivity. Energy savings were calculated using an empirical energy and IEQ model calibrated with sensed data from the building. Evaluation of the full IEQ þ DLCA framework suggested potentially significant energy savings potential and possible productivity enhancement, but indicated tradeoffs between internal chemical impact categories related to building ventilation, indoor pollutant generation and outdoor pollutant intake. The tradeoffs and overlaps between internal chemical impact categories themselves, as well as between chemical and non-chemical impact categories such as (SBS) are a challenge for LCA of whole buildings. © 2014 Elsevier Ltd. All rights reserved.
منابع مشابه
Re-evaluation of a LEED Platinum Building: Occupant experiences of health and comfort.
BACKGROUND There is a need to better understand the perceived experiences of workers in green buildings as the literature to this point has been mixed. OBJECTIVES To re-evaluate occupant experiences within a LEED platinum building and investigate current experiences in general. METHODS An online post occupancy evaluation (POE) survey of 62 occupants of LEED Platinum building on a US college...
متن کاملEvaluation of Environmental Sustainability Components and Architecture Design of Iranian Educational Buildings
Aims & Backgrounds: Today, environmental developments, climate change, and energy problems are major challenges in the world. Although Iran has been at the beginning of sustainable development regarding the buildings sustainability evaluation systems and has developed general guidelines and standards in this area, no effective action has been taken about schools. The present study aim is to det...
متن کاملInvestigating the Effects of Environmental Factors on Office Buildings’ Indoor Environment Quality in Iran’s Cold Climate (Case study: Kermanshah)
The inappropriate indoor environmental quality of a building causes different problems such asheadache and breathing difficulties which are called the syndrome of building sickness. These diseases reduce the efficiency of people and deteriorate the quality of their life. Studies carried out in hundreds of big office buildings across the world show that the indoor environment qualities of these ...
متن کاملEvaluation of Criteria for Determining the Buildings Height in Hamedan's Detailed Plan with Energy Efficiency Aspect Based on the TOPSIS
Many cities in the world are involved with air pollution and environmental pollution. The consumption of fossil fuels in buildings has an enormous impact on the pollution. About 40% of the total energy is spent on heating, cooling and lighting of buildings. The use of solar energy is one of the ways that reduce the thermal load of buildings. One of the factors that affect this utilization is th...
متن کاملفرایند دستیابی به نمای دوپوستۀ دارای بهره وری مناسب انرژی، نمونه موردی یک ساختمان اداری در تهران
Double Skin Façades (DSF) is one potential response to two major problems, i.e., low Indoor Environmental Quality (IEQ) and high energy consumption. The second skin provides thermal comfort, optimal sound performance, and better day lighting and ventilation. Many typologies of DSFs are widely used mostly in countries of cold climates. In Iran, however, they are less known, and therefore,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -