Raman and Photoemission Spectroscopic Analyses of Explanted Biolox® Delta Femoral Heads Showing Metal Transfer

نویسندگان

  • Paola Taddei
  • Eleonora Pavoni
  • Saverio Affatato
چکیده

Biolox® delta has been widely used in joint replacements thanks to its high strength and wear resistance. In this study, eleven Biolox® delta femoral head retrievals affected by metal transfer (MT) were analysed by Raman spectroscopy to estimate the tetragonal to monoclinic zirconia phase transformation, whose occurrence may compromise ceramic chemical stability and mechanical strength. The residual stress state was evaluated by both Raman and photoemission spectroscopy. Vm monoclinic zirconia contents were higher near the centre of the articulating surface and in the MT area than in the border control area of the retrievals. In only one retrieval, stress related to MT appeared a more severe condition, able to induce zirconia phase transformation; for all the others, stresses related to loading in the central region and related to MT, were conducive to a zirconia phase transformation of nearly the same extent. Vm depth profiling analyses showed that the transformation involved different thicknesses in different samples. Raman data allowed for the investigation of the mechanism of zirconia phase transformation and confirmed that the growth stage was absent and the nucleation stage was not occurring as freely as it would in unconstrained zirconia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vitro versus In Vivo Phase Instability of Zirconia-Toughened Alumina Femoral Heads: A Critical Comparative Assessment

A clear discrepancy between predicted in vitro and actual in vivo surface phase stability of BIOLOX®delta zirconia-toughened alumina (ZTA) femoral heads has been demonstrated by several independent research groups. Data from retrievals challenge the validity of the standard method currently utilized in evaluating surface stability and raise a series of important questions: (1) Why do in vitro h...

متن کامل

Tribological and material analyses of retrieved alumina and zirconia ceramic heads correlated with polyethylene wear after total hip replacement.

It has been suggested that the wear of ultra-high molecular weight polyethylene (UHMWPE) in total hip replacement is substantially reduced when the femoral head is ceramic rather than metal. However, studies of alumina and zirconia ceramic femoral heads on the penetration of an UHMWPE liner in vivo have given conflicting results. The purpose of this study was to examine the surface characterist...

متن کامل

Does Metal Transfer Differ on Retrieved Ceramic and CoCr Femoral Heads?

Metal transfer has been observed on retrieved THA femoral heads for both CoCr and ceramic bearing materials. In vitro wear testing has shown increased wear to polyethylene acetabular liners with the presence of metal transfer. This study sought to investigate the extent of metal transfer on the bearing surface of CoCr and ceramic femoral heads and identify prevalent morphologies. Three bearing ...

متن کامل

Surface Roughness of CoCr and ZrO2 Femoral Heads with Metal Transfer: A Retrieval and Wear Simulator Study

Metal transfer to femoral heads may result from impingement against the metallic acetabular shell following subluxation/dislocation, or when metallic debris enters the articulation zone. Such transfers roughen the head surface, increasing polyethylene wear in total hip replacements. Presently, we examined the surface roughness of retrieved femoral heads with metallic transfer. Profilometry reve...

متن کامل

Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components.

This study reports on ceramic-on-metal (CoM) bearings in total hip replacement. Whole blood metal ion levels were measured. The median increase in chromium and cobalt at 12 months was 0.08 microg/1 and 0.22 microg/1, respectively, in CoM bearings. Comparable values for metal-on-metal (MoM) were 0.48 microg/1 and 0.32 microg/1. The chromium levels were significantly lower in CoM than in MoM bear...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2017