Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion.

نویسندگان

  • Rajesh K Bindal
  • Sharon Glaze
  • Meghann Ognoskie
  • Van Tunner
  • Robert Malone
  • Subrata Ghosh
چکیده

OBJECT Minimally invasive transforaminal lumbar interbody fusion (TLIF) is an increasingly popular procedure. The technique involves use of fluoroscopy to assist with pedicle screw (PS) placement. The potential exists for both the surgeon and the patient to become exposed to significant amounts of radiation. The authors undertook this study to quantify the radiation dose to the surgeon and patient during minimally invasive TLIF. METHODS The authors undertook a prospective study of 24 consecutive patients who underwent minimally invasive TLIF. All surgeries were performed by the senior author (R.K.B.), who used techniques previously described. The surgeon wore a radiation monitor under an apron-style lead shield at waist level, at an unshielded collar location, and as a sterile ring badge containing a thermoluminescent dosimeter on the dominant (right) hand ring finger. Dosimeter readings were obtained for each case. A total of 33 spinal levels were treated in 24 patients. All treated levels were between L3-4 and L5-S1. In all cases of 1-level disease, 4 PSs were placed, and in all cases of 2-level disease, 6 screws were placed. RESULTS Mean fluoroscopy time was 1.69 minutes per case (range 3.73-0.82 minutes). Mean exposure per case to the surgeon on his dominant hand was 76 mRem, at the waist under a lead apron was 27 mRem, and at an unprotected thyroid level was 32 mRem. Mean exposure to the patient's skin was 59.5 mGy (range 8.3-252 mGy) in the posteroanterior plane and 78.8 mGy (range 6.3-269.5 mGy) in the lateral plane. CONCLUSIONS To the authors' knowledge, this is the first study of radiation exposure to the surgeon or patient in minimally invasive TLIF. Patient exposures were low and compare favorably with exposures involving other common interventional fluoroscopically guided procedures. Surgeon exposures are limited but require careful monitoring. Annual dose limits could be exceeded if a large number of these and other fluoroscopically guided procedures were performed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of Minimally Invasive Spine Surgery in Adults with Degenerative Lumbar Scoliosis: A Narrative Review

Background and Aim: Degenerative lumbar scoliosis is a spinal deformity resulting from advanced disc degeneration and facet arthropathy. Given the inconclusive available literature and lack of high-quality data supporting the role of minimally invasive surgical management of degenerative lumbar scoliosis, this review intends to highlight and compare the various viable minimally invasive surgica...

متن کامل

Surgeon, staff, and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion: impact of 3D fluoroscopy-based navigation partially replacing conventional fluoroscopy: study protocol for a randomized controlled trial

BACKGROUND Some symptomatic degenerative conditions of the lumbar spine may be treated with spinal fusion if conservative treatment has failed. The minimally invasive technique of transforaminal lumbar interbody fusion (MIS TLIF) is increasingly used but has been found to generate increased radiation exposure to the patient and staff. Modern three-dimensional (3D) C-arm devices are capable of p...

متن کامل

Minimally Invasive Transforaminal Lumbar Interbody Fusion – An Overview of its Benefits and Pitfalls

Minimally invasive spine surgery has been on the rise in the last decade, providing the auditorium of spine surgeons with state of the art solutions to common clinical situations. Avoiding extensive soft tissue injury in miniopen Transforaminal lumbar interbody fusion (TLIF) resulted in measurable clinical benefits like decrease of blood loss, less pain and faster rehabilitation postoperatively...

متن کامل

Minimally invasive transforaminal lumbar interbody fusion: indications, technique, and complications.

The authors provide an overview of the minimally invasive transforaminal lumbar interbody fusion (TLIF) procedure including indications, technique, and complications. This novel technique is a method of achieving circumferential lumbar fusion using a unilateral dorsal approach. Minimally invasive TLIF uses a tubular retractor that is inserted via a muscle-dilating exposure, thereby minimizing t...

متن کامل

Classification of Minimally Invasive Techniques for Transforaminal Lumbar Interbody Fusion

Minimally-invasive techniques for transforaminal lumbar interbody fusion have been shown to reduce intra-operative blood loss, muscle injury, post-operative pain and length-ofstay and expedite recovery compared to the open technique [1-11]. The main drawback has been increased intra-operative radiation exposure due to reliance on bi-planar fluoroscopy that is required to compensate for diminish...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgery. Spine

دوره 9 6  شماره 

صفحات  -

تاریخ انتشار 2008