Legionella pneumonia due to exposure to 24-hour bath water contaminated by Legionella pneumophila serogroup-5.
نویسندگان
چکیده
A 79-year-old man was admitted to hospital from his nursing home for treatment of pneumonia, but died 7 days after admission. Legionella pneumonia was diagnosed after isolation of Legionella pneumophila serogroup-5 from sputum culture. The environment of the nursing home was investigated; only water specimens from the 24-hour bath were positive by culture for Legionella pneumophila serogroup-5. Subsequent analysis by pulsed-field gel electrophoresis revealed an identical pattern in isolates from both sputum culture and 24 hour bath water culture. Among 123 inpatients and staff of the nursing home, 17 were found to be seropositive for Legionella pneumophila serogroup-5.
منابع مشابه
Two Legionnaires' disease cases associated with industrial waste water treatment plants: a case report
BACKGROUND Finnish and Swedish waste water systems used by the forest industry were found to be exceptionally heavily contaminated with legionellae in 2005. CASE PRESENTATION We report two cases of severe pneumonia in employees working at two separate mills in Finland in 2006. Legionella serological and urinary antigen tests were used to diagnose Legionnaires' disease in the symptomatic emplo...
متن کاملLegionellosis from Legionella pneumophila Serogroup 13
We describe 4 cases of Legionella pneumophila serogroup 13-associated pneumonia. These cases originate from a broad geographic range that includes Scotland, Australia, and New Zealand. L. pneumophila serogroup 13 pneumonia has a clinically diverse spectrum that ranges from relatively mild, community-acquired pneumonia to potentially fatal severe pneumonia with multisystem organ failure. All cas...
متن کاملHot spring bath as the reservoir of Legionella bacterium.
Legionella are widely distributed in natural and man-made environments. In these environments, legionella can utilize metabolic products excreted by blue-green algae and other general bacteria, on the other hand they can multiply intracellularly within amoebaebody. The major infection route of legionella is via 1-5 |Lim diameter aerosols which contain the legionella and reach humanalveolar sept...
متن کاملNeonatal sudden death due to Legionella pneumonia associated with water birth in a domestic spa bath.
We report the first case of neonatal Legionnaires' disease associated with water birth in a spa bath at home. Legionella pneumophila serogroup 6 was detected from postmortem lung tissue.
متن کاملLegionnaires’ disease after using an industrial pressure test pump: a case report
INTRODUCTION Legionnaires' disease is an acute pneumonia caused by inhalation or aspiration of aerosols contaminated with Legionella bacteria. The majority (>90%) of Legionnaires' disease cases are caused by the species Legionella pneumophila, and about 85% more specifically by L. pneumophila serogroup 1 that can be detected by a fast and easy to perform urinary antigen test. Previously reporte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Internal medicine
دوره 44 6 شماره
صفحات -
تاریخ انتشار 2005