Mass balance analysis of contaminated heparin product.

نویسندگان

  • Zhenling Liu
  • Zhongping Xiao
  • Sayaka Masuko
  • Wenjing Zhao
  • Eric Sterner
  • Vinod Bansal
  • Jawed Fareed
  • Jonathan Dordick
  • Fuming Zhang
  • Robert J Linhardt
چکیده

A quantitative analysis of a recalled contaminated lot of heparin sodium injection U.S. Pharmacopeia (USP) was undertaken in response to the controversy regarding the exact nature of the contaminant involved in the heparin (HP) crisis. A mass balance analysis of the formulated drug product was performed. After freeze-drying, a 1-ml vial for injection afforded 54.8±0.3 mg of dry solids. The excipients, sodium chloride and residual benzyl alcohol, accounted for 11.4±0.5 and 0.9±0.5 mg, respectively. Active pharmaceutical ingredient (API) represented 41.5±1.0 mg, corresponding to 75.7 wt% of dry mass. Exhaustive treatment of API with specific enzymes, heparin lyases, and/or chondroitin lyases was used to close mass balance. HP represented 30.5±0.5 mg, corresponding to 73.5 wt% of the API. Dermatan sulfate (DS) impurity represented 1.7±0.3 mg, corresponding to 4.1 wt% of API. Contaminant, representing 9.3±0.1 mg corresponding to 22.4 wt% of API, was found in the contaminated formulated drug product. The recovery of contaminant was close to quantitative (95.6-100 wt%). A single contaminant was unambiguously identified as oversulfated chondroitin sulfate (OSCS).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of Chemically Sulfated/desulfated Glycosaminoglycans in Contaminated Heparins and Development of a Simple Assay for the Detection of Most Contaminants in Heparin.

Contaminated heparin was linked to at least 149 deaths and hundreds of adverse reactions. Published report indicates that heparin contaminants were a natural impurity, dermatan sulfate, and a contaminant, oversulfated chondroitin sulfate (OSCS). OSCS was assumed to derive from animal cartilage. By analyzing 26 contaminated heparin lots from different sources, our data indicate that the heparin ...

متن کامل

High-throughput differentiation of heparin from other glycosaminoglycans by pyrolysis mass spectrometry.

Sensors with high chemical specificity and enhanced sample throughput are vital to screening food products and medical devices for chemical or biochemical contaminants that may pose a threat to public health. For example, the rapid detection of oversulfated chondroitin sulfate (OSCS) in heparin could prevent reoccurrence of heparin adulteration that caused hundreds of severe adverse events incl...

متن کامل

Top-down and bottom-up analysis of commercial enoxaparins.

A strategy for the comprehensive analysis of low molecular weight (LMW) heparins is described that relies on using an integrated top-down and bottom-up approach. Liquid chromatography-mass spectrometry, an essential component of this approach, is rapid, robust, and amenable to automated processing and interpretation. Nuclear magnetic resonance spectroscopy provides complementary top-down inform...

متن کامل

High-sensitivity visualisation of contaminants in heparin samples by spectral filtering of 1H NMR spectra.

A novel application of two-dimensional correlation analysis has been employed to filter (1)H NMR heparin spectra distinguishing acceptable natural variation and the presence of foreign species. Analysis of contaminated heparin samples, compared to a dataset of accepted heparin samples using two-dimensional correlation spectroscopic analysis of their 1-dimensional (1)H NMR spectra, allowed the s...

متن کامل

Reducing Agents Enhanced Electrokinetic Soil Remediation (EKSR) for Heavy Metal Contaminated Soil

Reducing agents-Enhanced electrokinetic Soil Remediation (EKSR) was performed for the removal of chromium (Cr), cobalt (Co) and nickel (Ni) from contaminated soil. The reducing agents oxalic acid and ascorbic acid were investigated under constant voltage gradient (2.0 V/cm), current changes, pH, redox potential, concentration changes and removal performance of Heavy Metals (HMs). The result...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical biochemistry

دوره 408 1  شماره 

صفحات  -

تاریخ انتشار 2011