Hemodynamic analysis of sequential graft from right coronary system to left coronary system

نویسندگان

  • Wenxin Wang
  • Boyan Mao
  • Haoran Wang
  • Xueying Geng
  • Xi Zhao
  • Huixia Zhang
  • Jinsheng Xie
  • Zhou Zhao
  • Bo Lian
  • Youjun Liu
چکیده

BACKGROUND Sequential and single grafting are two surgical procedures of coronary artery bypass grafting. However, it remains unclear if the sequential graft can be used between the right and left coronary artery system. The purpose of this paper is to clarify the possibility of right coronary artery system anastomosis to left coronary system. METHODS A patient-specific 3D model was first reconstructed based on coronary computed tomography angiography (CCTA) images. Two different grafts, the normal multi-graft (Model 1) and the novel multi-graft (Model 2), were then implemented on this patient-specific model using virtual surgery techniques. In Model 1, the single graft was anastomosed to right coronary artery (RCA) and the sequential graft was adopted to anastomose left anterior descending (LAD) and left circumflex artery (LCX). While in Model 2, the single graft was anastomosed to LAD and the sequential graft was adopted to anastomose RCA and LCX. A zero-dimensional/three-dimensional (0D/3D) coupling method was used to realize the multi-scale simulation of both the pre-operative and two post-operative models. RESULTS Flow rates in the coronary artery and grafts were obtained. The hemodynamic parameters were also showed, including wall shear stress (WSS) and oscillatory shear index (OSI). The area of low WSS and OSI in Model 1 was much less than that in Model 2. CONCLUSIONS Model 1 shows optimistic hemodynamic modifications which may enhance the long-term patency of grafts. The anterior segments of sequential graft have better long-term patency than the posterior segments. With rational spatial position of the heart vessels, the last anastomosis of sequential graft should be connected to the main branch.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computer-Aided Patient-Specific Coronary Artery Graft Design Improvements Using CFD Coupled Shape Optimizer

This study aims to (i) demonstrate the efficacy of a new surgical planning framework for complex cardiovascular reconstructions, (ii) develop a computational fluid dynamics (CFD) coupled multi-dimensional shape optimization method to aid patient-specific coronary artery by-pass graft (CABG) design and, (iii) compare the hemodynamic efficiency of the sequential CABG, i.e., raising a daughter par...

متن کامل

The effect of cardiac rehabilitation on hemodynamic status in patients after coronary artery bypass surgery

Background: Today, coronary artery bypass graft surgery (CABG) in many patients is commonly used to treat complications of the disease. Aim: This study aimed to evaluate the impact of cardiac rehabilitation on hemodynamic parameters in patients undergoing CABG. Methods: : In this clinical trial which was conducted in Rajaee Hospital of Tehran University of Medical Sciences 100 patients after co...

متن کامل

مقایسه‌ی نتایج استفاده از شانت داخل عروق کرونر در عمل بای‌پس عروق کرونر بدون پمپ نسبت به عدم استفاده از آن

Background and Objective: Off pump coronary artery bypass graft can be done with or without using intracoronary shunt. We have compared these two methods in early postoperative period, in this study. Materials and Methods: 208 candidate patients for off pump coronary artery bypass graft were devided in to two groups randomly for using intracoronary shunt or not. Variables including peri and pos...

متن کامل

Correlation between Coronary Artery Bypass Graft Surgery and Hearing Threshold Changes

Introduction: Sensorineural hearing loss (SNHL) is a probable complication of coronary artery bypass graft (CABG) Surgery, that may be due to embolism, perfusion failure and consumption of ototoxic drugs. Since the incidence of SNHL after CABG is different according to the various reports, the present study was designed to study hearing threshold change after CABG surgery. Method: In this cross...

متن کامل

Incidence of Atrial Fibrillation after Coronary Artery Bypass Graft Surgery and Its Risk Factors in Shiraz, Iran during 2017-18

Background and Objectives: Atrial fibrillation is one of the most common disorientations after coronary artery bypass graft surgery and can affect the chance of survival in the first year after surgery. The present study aimed to determine the incidence of atrial fibrillation after coronary artery bypass graft surgery and its risk factors.   Methods: This cross-sectional study was performed on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2016