Colonoscopy quality assessment.

نویسندگان

  • S Morán Sánchez
  • E Torrella
  • P Esteban Delgado
  • R Baños Madrid
  • A García
  • A Ono
  • E Pérez Cuadrado
  • P Parra
  • J Cruzado Quevedo
  • F Pérez Riquelme
  • F Carballo Alvarez
چکیده

AIM Colonoscopy has become accepted as the most effective method for colon exploration. Some application problems have been detected in the setting of normal clinical care due to its wide range of uses in recent years, and therefore there is a need to measure colonoscopy quality. For that purpose valid quality indicators are necessary to be defined. The application process of some quality indicators is presented in this study. The proposed indicators in this study are: quality of bowel preparation, cecal intubation rate, withdrawal time, adenoma detection rate, and adenoma removal rate. MATERIAL AND METHOD This is a prospective 12-month study where colonoscopies performed in the VI health area of Murcia Region were evaluated. From February 2006 to February 2007 a total of 609 subjects were eligible for colonoscopy after a positive fecal blood test in the setting of a colorectal cancer screening program. A sample of thirty patients (n: 30) was considered representative to assess the reliability of quality indicators and for a preliminary analysis of results. RESULTS Indicators results are: quality of bowel preparation (87%), kappa 0.74 (95% CI: 0.48-0.99); cecal intubation rate (90%) 0.74 (95% CI: 0.49-0.99); adenoma detection and removal rate (96%), kappa: 0.78 (95% CI: 0.53-0.99); withdrawal time: 13.36 min (95% CI: 10.48-16.11). Kappa: 0.78 (95% CI: 0.49-0.99). CONCLUSIONS Quality indicators definition and application in colonoscopy performance is possible. More studies are necessary to define the role of these indicators in the setting of clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Colonoscopy quality assessment.

Colonoscopy is the cornerstone of colorectal cancer screening programs. There is significant variability in the quality of colonoscopy between endoscopists. Colonoscopy quality assessment tracks various metrics to improve the effectiveness of colonoscopy, aiming at reducing the incidence and mortality from colorectal cancer. Adenoma detection rate is the prime metric, because it is associated w...

متن کامل

Quality Indicators for Colonoscopy Procedures

Colonoscopy remains the gold standard for morphologic colon. Despite the development of new methods of morphologic bowel, colonoscopy is still considered the « gold standard » because of its ability at detecting small neoplasic lesions as well as adenomas. Unlike other methods, colonoscopy has the great advantage of carrying out the same time the removal of polyps. Colonoscopy also has a number...

متن کامل

Endoscopist-related factors contributing to high-quality colonoscopy: results of a Delphi survey

Education and competency assessment in gastrointestinal endoscopy is important. Concerning colonoscopy, it is not completely clear what the best way is to learn this procedure, what defines competency in colonoscopy, and which factors define a high-quality colonoscopy. The aim of this study was to determine the endoscopist-related factors that define a high-quality colonoscopy. A three-round De...

متن کامل

An explorative study from the Norwegian Quality Register Gastronet comparing self-estimated versus registered quality in colonoscopy performance.

BACKGROUND AND STUDY AIMS The value of a colonoscopy quality assurance (QA) register may be questioned if it brings no new information on which to act for quality improvement, e. g. if self-assessed quality of colonoscopy performance correlates perfectly with registered performance. PATIENTS AND METHODS In this explorative study, 39 (33 Norwegian and 6 Swedish) out of 99 new endoscopists join...

متن کامل

مقایسه اثرات آرام‌بخشی پروپوفول- فنتانیل با میدازولام– مپریدین در بیماران تحت کولونوسکوپی انتخابی

Background and purpose: Colonoscopy is an invasive short-lasting procedure causes the patient's considerable pain, discomfort and anxiety. Therefore, various types of sedation and analgesia techniques have been used during the procedure. The aim of this study was to compare the quality of sedation/analgesia of propofol-fentanyl and midazolam-meperidine combinations in patients undergoing electi...

متن کامل

Quality Assessment of Colonoscopy Reporting: Results from a Statewide Cancer Screening Program

This paper aimed to assess quality of colonoscopy reports and determine if physicians in practice were already documenting recommended quality indicators, prior to the publication of a standardized Colonoscopy Reporting and Data System (CO-RADS) in 2007. We examined 110 colonoscopy reports from 2005-2006 through Maryland Colorectal Cancer Screening Program. We evaluated 25 key data elements rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de enfermedades digestivas : organo oficial de la Sociedad Espanola de Patologia Digestiva

دوره 101 2  شماره 

صفحات  -

تاریخ انتشار 2009