Diagnostic performance of focused cardiac ultrasound performed by emergency physicians for the assessment of ascending aorta dilation and aneurysm.
نویسندگان
چکیده
OBJECTIVES The diagnostic performance of transthoracic focused cardiac ultrasound (FoCUS) performed by emergency physicians (EP) to estimate ascending aorta dimensions in the acute setting has not been prospectively studied. The diagnostic accuracy and the interobserver variability of EP-performed FoCUS were investigated to estimate thoracic aortic dilation and aneurysm compared with the results of computed tomography angiography (CTA). METHODS This was a prospective single-center cohort study of a convenience sample of patients who underwent CTA in the emergency department for suspected aortic pathology. FoCUS was performed before CTA, and the maximum ascending aorta diameter evaluated in parasternal long-axis view. Aorta diameter < 40 mm by visual estimation or by diameter measurement was considered normal. Measurements were recorded in all patients with aorta diameter ≥ 40 mm. Diagnostic accuracy of FoCUS for detection of aortic dilation (diameter ≥ 40 mm) and aneurysm (diameter ≥ 45 mm) were calculated considering the CTA result as reference standard. In a subgroup of patients, a second EP-sonographer performed FoCUS to evaluate interobserver agreement for the diagnosis of ascending aorta dilation. RESULTS A total of 140 patients were enrolled in the study. Ascending aorta dilation and aneurysm were detected with FoCUS in 50 (35.7%) and in 27 (17.8%) patients, respectively. Sensitivity and specificity of FoCUS were 78.6% (95% confidence interval [CI] = 65.6% to 88.4%) and 92.9% (95% CI = 85.1% to 97.3%), respectively, for ascending aorta dilation and 64.7% (95% CI = 46.5% to 80.2%) and 95.3% (95% CI = 89.3% to 98.4%), respectively, for ascending aorta aneurysm. Interobserver agreement of FoCUS was k = 0.82. CONCLUSIONS FoCUS performed by EP is specific for ascending aorta dilation and aneurysm when compared to CTA and appears a reproducible technique.
منابع مشابه
Diagnostic performance of focused cardiac ultrasound performed by emergency physicians for the assessment of ascending aorta dilatation and aneurysm
Patients and methods This was a prospective single-centre cohort study of a convenience sample of patients that underwent CTA in the emergency department for suspected aortic pathology. FOCUS was performed before CTA and the maximum ascending aorta diameter measured in parasternal longaxis view. Diagnostic accuracy of FOCUS for detection of aortic dilation (diameter ≥40 mm) and aneurysm (diamet...
متن کاملPoint-of-care focused cardiac ultrasound for the assessment of thoracic aortic dimensions, dilation, and aneurysmal disease.
OBJECTIVES Thoracic aortic aneurysm and thoracic aortic dissection are related and potentially deadly diseases that present with nonspecific symptoms. Transthoracic echocardiography (TTE) may detect thoracic aortic pathology and is being increasingly performed by the emergency physician at the bedside; however, the accuracy of point-of-care (POC) focused cardiac ultrasound (FOCUS) for thoraci...
متن کاملAortic Pseudo aneurysm 3 Years after Interposition Tube Graft for Acute Dissection of Ascending Aorta
Introduction: Patients with primary acute aortic dissection are at higher risk of complications, including increasing aortic aneurysm diameter, aortic rupture, aortic pseudo aneurysm, and recurrent aortic dissection. Case presentation We presented the case of a recurrent pseudo aneurysm and rupture of the aorta in the distal a...
متن کاملFocused cardiac ultrasound diagnosis of thoracic aortic aneurysm: two cases.
BACKGROUND Thoracic aortic aneurysms (TAAs) are less prevalent than abdominal aortic aneurysms. Symptomatic TAAs need to be identified quickly by the emergency physician (EP) since mortality rates increase dramatically once complications such as rupture or dissection occur. Compared with validated EP-performed ultrasound of the abdominal aorta, EP-performed focused cardiac ultrasound that inclu...
متن کاملEmergency ultrasound of the abdominal aorta by UK emergency physicians: a prospective cohort study.
OBJECTIVE To establish whether UK emergency physicians could reliably perform focused ultrasound of the abdominal aorta in patients with suspected abdominal aortic aneurysm (AAA). METHODS A prospective cohort study was conducted in the emergency department of a tertiary level UK teaching hospital. All patients who underwent an abdominal aortic ultrasound by an emergency physician during a 12 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Academic emergency medicine : official journal of the Society for Academic Emergency Medicine
دوره 22 5 شماره
صفحات -
تاریخ انتشار 2015