Measurement of post-lens tear thickness.

نویسندگان

  • M C Lin
  • A D Graham
  • K A Polse
  • R B Mandell
  • N A McNamara
چکیده

PURPOSE A method to measure the tear film beneath a soft contact lens, referred to as post-lens tear thickness (PLTT), would have many applications to contact lens research. In this study a noninvasive technique for measuring the PLTT is presented. METHODS The feasibility of measuring the tear layer by optical pachometry was first assessed using a model eye. The baseline corneal thickness (B) of both eyes of 21 subjects was measured, etafilcon-A ionic disposable soft contact lenses (58% water) were inserted, and the total thickness (T) of the cornea, contact lens, and PLTT were measured. After the pachometry readings the lenses were removed and their center thickness (C) determined. The PLTT was calculated using the equation: PLTT = T-(B+C). Two sets of measurements of T were performed at 15 and 25 minutes after lens insertion. The entire procedure was repeated at a second visit. RESULTS The pachometry measurements of the small aqueous reservoir between the model eye and the lens closely matched those obtained by direct microscopic measurement. For human PLTT, the mean values (and 95% confidence intervals) for right eyes on visits 1 and 2 were 11 (8, 13) and 12 (10, 15) microm, respectively, and for left eyes were 12 (10, 15) and 11 microm (8, 14) microm, respectively. CONCLUSIONS It is possible to measure the post-lens tear thickness using optical pachometry. The variability between repeated measurements suggests that with careful sample size planning, the technique is sufficiently precise to be useful in group assessments of PLTT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Post-lens tear turbidity and visual quality after scleral lens wear.

BACKGROUND The aim was to evaluate the turbidity and thickness of the post-lens tear layer and its effect on visual quality in patients with keratoconus after the beginning of lens wear and before lens removal at the end of eight hours. METHODS Twenty-six patients with keratoconus (aged 36.95 ± 8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients...

متن کامل

Thickness of the pre- and post-contact lens tear film measured in vivo by interferometry.

PURPOSE To evaluate an interferometric method for measuring the thickness of the pre- (PLTF) and postlens tear film (POLTF) in subjects wearing hydrogel contact lenses. The precision and accuracy of measuring postlens tear thickness is compared with a previous method based on optical pachymetry and mechanical measurement of contact lens thickness. METHODS Reflectance spectra (562-1030 nm) fro...

متن کامل

Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.

PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9...

متن کامل

Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses.

Purpose. To determine the dynamic pre- and postlens tear film (PLTF and PoLTF) thicknesses by using optical coherence tomography (OCT). Methods. Ultrahigh-resolution OCT was used to image the tear film of 22 subjects before and after contact lens wear. A soft lens with 1 drop of artificial tears on its concave surface was inserted onto one randomly selected eye. OCT images were taken before ins...

متن کامل

The effects of ocular and lens parameters on the postlens tear thickness.

PURPOSE To assess the effects of soft contact lens base curve radius (BCR), sex, ethnicity, central corneal curvatures, and vertical palpebral aperture size (PAS) on the postlens tear thickness (PLTT). METHODS The PLTT was measured using optical pachometry on 114 experienced lens wearers who were fitted with lathe-cut soft lenses (Alden 47, polymacon, 35.5% H2O, -2.00 diopter, and 14.0 mm). E...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 40 12  شماره 

صفحات  -

تاریخ انتشار 1999