Spontaneous hyphema and pupillary block in a patient with a left ventricular assist device.

نویسندگان

  • Shaheen C Kavoussi
  • Ji Liu
چکیده

The left ventricular assist device (LVAD) has been a standard of care for the management of patients with advanced heart failure since the 1990s. An increased risk of spontaneous bleeding related to the device has been noted, ranging from minor epistaxis to major thoracic and mediastinal hemorrhages. To our knowledge, intraocular hemorrhage has not been previously reported. We report a 72-year-old patient with an LVAD who subsequently developed a spontaneous intraocular hemorrhage that manifested as hyphema, pupillary block, and acute intraocular pressure elevation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Permanent pacing in a patient with a left ventricular assist system.

A patient with end stage heart failure underwent permanent implantation of a Novacor left ventricular assist system. Progressive right ventricular dysfunction developed during the first two postoperative weeks. Temporary and subsequently permanent atrioventricular pacing to correct first degree heart block improved the performance of the device, with sustained resolution of his right ventricula...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Digital journal of ophthalmology : DJO

دوره 21 2  شماره 

صفحات  -

تاریخ انتشار 2015