Pulmonary vein isolation using the Rhythmia mapping system: Verification of intracardiac signals using the Orion mini-basket catheter.

نویسندگان

  • Elad Anter
  • Cory M Tschabrunn
  • Fernando M Contreras-Valdes
  • Jianqing Li
  • Mark E Josephson
چکیده

BACKGROUND During pulmonary vein isolation (PVI), a circular lasso catheter is positioned at the junction between the left atrium (LA) and the pulmonary vein (PV) to confirm PVI. The Rhythmia mapping system uses the Orion mini-basket catheter with 64 electrodes instead of the lasso catheter. However, its feasibility to determine PVI has not been studied. OBJECTIVE The purpose of this study was to compare signals between the mini-basket and lasso catheters at the LA-PV junction. METHODS In 12 patients undergoing PVI using Rhythmia, the mini-basket and lasso catheters were placed simultaneously at the LA-PV junction for baseline and post-PVI signal assessment. Pacing from both catheters was performed to examine the presence of exit block. RESULTS At baseline, recordings of LA and PV potentials were concordant in all PVs. However, after PVI, concordance between the catheters was only 68%. Discordance in all cases resulted from loss of PV potentials on the lasso catheter with persistence of PV potentials on the mini-basket catheter. In 9 of 13 PVs (69%), these potentials represented true PV potentials that were exclusively recorded with the smaller and closely spaced mini-basket electrodes. In the other 4 PVs (31%), these potentials originated from neighboring structures and resulted in underestimation of PVI. CONCLUSION The use of the mini-basket catheter alone is sufficient to determine PVI. While it improves recording of PV potentials after incomplete ablation, it is also associated with frequent recording of "PV-like" potentials originating from neighboring structures. In these cases, pacing maneuvers are helpful to determine PVI and avoid excessive ablation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The electrical circuit of a hemodynamically unstable and recurrent ventricular tachycardia diagnosed in 35 s with the Rhythmia mapping system

Herein, we report a 47-year-old woman with ischemic cardiomyopathy who underwent ablation therapy due to an electrical storm without any triggers. The voltage mapping in sinus rhythm with the Rhythmia system and Orion catheter displayed several LAVAs in and around the anteroapical scar area. Although the patient did not tolerate the induced clinical ventricular tachycardia, which was reproducti...

متن کامل

Pulmonary Vein Isolation with a Multielectrode Basket Catheter

Pulmonary vein (PV) isolation (PVI) techniques have evolved as a curative treatment of atrial fibrillation (AF) since PVI guided by circumferential mapping with a circular catheter was initially proposed. A multielectrode basket catheter (MBC) is also useful for PVI because of some advantages; (1) an MBC provides some information about the PV anatomy on the fluoroscopic image, (2) an MBC can ut...

متن کامل

Small or large isolation areas around the pulmonary veins for the treatment of atrial fibrillation? Results from a prospective randomized study.

BACKGROUND Pulmonary vein (PV) isolation is a promising new treatment for atrial fibrillation (AF). We hypothesized that isolation of large areas around both ipsilateral PVs with verification of conduction block is more effective than the isolation of each individual PV. METHODS AND RESULTS A total of 110 patients, 67 with paroxysmal AF and 43 with persistent AF, were randomly assigned to und...

متن کامل

Pulmonary vein potential mapping in atrial fibrillation with high density and standard spiral (lasso) catheters: A comparative study

BACKGROUND The dominant single-shot procedure for Pulmonary Vein Isolation (PVI) is the Cryoballoon Ablation (CBA) technique using a spiral catheter (Achieve™, AC) for mapping and monitoring purposes. We hypothesized that Basket Catheters, such as the High Density Mesh Mapper (HDMM), with its high-density mapping properties, could detect Pulmonary Vein Potentials (PVPs) that the octapolar AC wo...

متن کامل

An atypical mechanism of pseudo mitral isthmus block clarified by the high-resolution mapping system

A 31-year-old man with prior step-wise ablation for persistent atrial fibrillation presented with atrial tachycardia (AT). Linear lines for the mitral isthmus, left atrial roof, and the cavo-tricuspid isthmus had previously been performed in addition to pulmonary vein (PV) isolation and defragmentation on the left atrium. The patient was in sinus rhythm (SR) at the beginning of the procedure, s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Heart rhythm

دوره 12 9  شماره 

صفحات  -

تاریخ انتشار 2015