Changes in the anterior segment after cycloplegia with a biometer using swept-source optical coherence tomography

نویسندگان

  • Tomoaki Higashiyama
  • Maki Iwasa
  • Masahito Ohji
چکیده

The aim of this study was to investigate changes in the anterior segment of the eye after cycloplegia. A biometer combined with swept-source optical coherence tomography (SSOCT) was used for measurements. Patients with strabismus or amblyopia who underwent cycloplegia were included. The axial length, central corneal thickness, anterior chamber depth, and lens thickness were measured with the biometer-SSOCT system before and after cycloplegia. Altogether, 10 eyes of 10 patients (mean age 7.20 ± 3.08 years, range 4-14 years) were evaluated. The mean measurements before cycloplegia were 22.75 ± 0.96 mm axial length, 516 ± 33 μm central corneal thickness, 3.40 ± 0.21 mm anterior chamber depth, and 3.77 ± 0.26 mm lens thickness. The corresponding values after cycloplegia were 22.75 ± 0.95 mm, 519 ± 34 μm, 3.68 ± 0.16 mm, and 3.42 ± 0.20 mm, respectively. The mean lens thickness had significantly decreased (P < 0.001) after cycloplegia, and the mean anterior chamber depth had significantly increased (P < 0.001). The means of the axial length (P = 0.66) and central corneal thickness (P = 0.17) had not changed significantly. The change in lens thickness was significantly correlated with the change in anterior chamber depth (r = -0.73, P = 0.02). The new biometer-SSOCT combination proved useful for accurately detecting changes in the anterior segment of the eye after cycloplegia in pediatric patients. The biometer's measurements indicated increased anterior chamber depth and decreased lens thickness after cycloplegia. The anterior chamber depth increased relative to the decrease in lens thickness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology

PURPOSE The purpose of this study was to compare the central corneal thickness (CCT) measurements of four noncontact devices in healthy eyes. MATERIALS AND METHODS In a sample of 45 healthy controls, CCT was measured using an optical biometer (IOLMaster 700) based on swept-source optical coherence tomography (SS-OCT), high-resolution rotating Scheimpflug camera system (Pentacam HR), spectral-...

متن کامل

Utility of anterior segment swept-source optical coherence tomography for imaging eyes with antecedent ocular trauma

Purpose To evaluate the utility of swept source optical coherence tomography (SS-OCT) for the analysis of anterior segment structures in cases with previous traumatic eye injuries. Observations We report three eyes of three patients with anterior segment traumatic eye injury and highlight the role of SS-OCT in their evaluation and management. This technology enabled us to visualize the struct...

متن کامل

Assessment of Anterior Segment Measurements with Swept Source Optical Coherence Tomography before and after Ab Interno Trabeculotomy (Trabectome) Surgery

Purpose. To compare the changes of anterior segment parameters, assessed by swept source anterior segment optical coherence tomography (AS-OCT) after combined Trabectome-cataract surgery and Trabectome-only surgery in open angle glaucoma patients. Methods. Thirty-eight eyes of 24 patients with open angle glaucoma were scanned with swept source AS-OCT before and 4 weeks after combined Trabectome...

متن کامل

Imaging limbal and scleral vasculature using Swept Source Optical Coherence Tomography.

We demonstrate an application of high-speed swept source optical coherence tomography for vessel visualization in the anterior segment of the human eye. The human corneo-scleral junction and sclera was imaged in vivo. Imaging was performed using a swept source OCT system operating at the 1050nm wavelength range and 100kHz A-scan rate. High imaging speed enables the generation of 3D depth-resolv...

متن کامل

In vivo volumetric depth-resolved vasculature imaging of human limbus and sclera with 1μm swept source phase-variance optical coherence angiography.

We present nnnnnin vivo volumetric depth-resolved vasculature images of the anterior segment of the human eye acquired with phase-variance based motion contrast using a high-speed (100 kHz, 105 A-scans/s) swept source optical coherence tomography system (SSOCT). High phase stability SSOCT imaging was achieved by using a computationally efficient phase stabilization approach. The human corneo-sc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017