Optimal pupil size in the human eye for axial resolution.
نویسندگان
چکیده
A computer model that incorporates the monochromatic aberrations of the eye is used to determine the optimal pupil size for axial and lateral resolution as it applies to retinal imaging instruments such as the confocal scanning laser ophthalmoscope. The optimal pupil size for axial resolution, based on the aberrations of 15 subjects, is 4.30 mm +/- 1.19 mm standard deviation (sd), which is larger than that for lateral resolution [2.46 mm +/- 0.66 mm (sd)]. When small confocal pinholes are used, the maximum detected light is obtained with a pupil size of 4.90 mm +/- 1.04 mm sd. It is recommended to use larger pupil sizes in imaging applications where axial resolution is desired.
منابع مشابه
Development of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients
Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...
متن کاملIn vivo fluorescent imaging of the mouse retina using adaptive optics.
In vivo imaging of the mouse retina using visible and near infrared wavelengths does not achieve diffraction-limited resolution due to wavefront aberrations induced by the eye. Considering the pupil size and axial dimension of the eye, it is expected that unaberrated imaging of the retina would have a transverse resolution of 2 microm. Higher-order aberrations in retinal imaging of human can be...
متن کاملVisual axial PSF of diffractive trifocal lenses.
The ophthalmic applications of a diffractive trifocal lens design with adjustable add powers and light distribution in the foci are investigated. Axial PSFs of the trifocal lenses are calculated and analyzed as a function of the design parameters and the eye pupil size. The optical performance in actual eyes is also simulated by including the measured ocular wave aberration functions of human e...
متن کاملAdaptive Optics Confocal Scanning Laser Ophthalmoscope
Scanning laser ophthalmoscope (SLO) was first presented by R. H. Webb (R. H. Webb, et al, 1987) in 1987, which is the same as a scanning laser microscope except that human eye is used as the objective lens and retina is usually the sample being imaged. With its high contrast real-time imaging and axial sectioning capability, SLO has many advantages and applications in retina imaging (Austin. Ro...
متن کاملTo Estimate the Axial Elastic Modulus of Eye and Posterior Wall Thickness in Healthy Human Eye by Ultrasound Images and their Relation with Age and Gender
Introduction: Based on the invasive studies it has been shown that factors such as age, the progress of eye disorders, lens fibers compression and the biochemical changes of ocular matrix alter the physical characteristics and elastic properties of eye. In this study, a noninvasive method of estimating human eye elasticityis proposed and its relation with age and gender is evaluated using ultra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 20 11 شماره
صفحات -
تاریخ انتشار 2003