Evaluation of reliability of perioral muscle pressure measurements using a newly developed device with a lip piece.
نویسندگان
چکیده
PURPOSE We examined the reliability of measurements using a newly developed perioral muscle pressure measuring device with a lip piece in healthy adults. METHODS Subjects were 40 healthy men (25.8 years) with normal stomatognathic function. Perioral muscle pressure measuring device with a lip piece was used to measure upper lip, lower lip and tongue pressure, and a balloon-based measurement device was used to measure tongue and cheek pressure. Each measurement was taken twice with a 1-min interval between the two measurements. We determined intra-rater reliability by using the intra-class correlation coefficient as a test of relative reliability. As a test of absolute reliability, Bland-Altman analysis was used to assess systematic bias and the 95% confidence interval of the minimal detectable change was calculated. Additionally, the coefficient of variation was calculated. The Spearman-Brown formula was calculated the number of measurements needed to achieve a confidence coefficient ≥0.9. Each set of measurements was followed by a second set that were taken 1 week later. RESULTS All measurements showed high values of intra-class correlation coefficient. Upper lip, tongue, and cheek pressure can be determined based on a single measurement, while lower lip pressure requires averaging twice. No systematic bias was observed. The coefficients of variation of measurements were almost the same between the two devices. CONCLUSION Measurements were highly reliable regardless of the type of perioral muscles. Our findings suggest that the method described in this study is useful as a quantitative chair side method for examining perioral muscle pressure.
منابع مشابه
OroSTIFF: Face-referenced measurement of perioral stiffness in health and disease.
A new device and automated measurement technology known as OroSTIFF is described to characterize non-participatory perioral stiffness in healthy adults for eventual application to patients with orofacial movement disorders associated with neuromotor disease, traumatic injury, or congenital clefts of the upper lip. Previous studies of perioral biomechanics required head stabilization for extende...
متن کاملThe Intrarater Reliability of Rehabilitation Ultrasonography and Linear and Cross Sectional Measurements of the Lumbar Multifidus Muscles in Normal Subjects
Objective: Using rehabilitation ultrasonography imaging (RUSI) is widely growing in the physiotherapy clinics of developed countries. Due to this new application, it is necessary to consider the repeatability of this new technique by novice physiotherapists and applied methods to measure the muscle size. This study has been designed to investigate the intrarater reliability and also the relatio...
متن کاملبررسی تکرارپذیری نیروی عکس العمل زمین حین استفاده از ابزار اعمال اغتشاش اندام تحتانی در حرکت ایستادن روی یک پا
Introduction: The aim of the current study was to measure ground reaction force and center of pressure (COP) during lower extremity perturbation in single leg standing whit knee flexion and extension in healthy subjects, in addition to revealing reliability of the device used for the related perturbation for using another studies, reliability is one of the characteristic of measuring instrumen...
متن کاملIntra- and Inter-Rater Reliability of Micro Manual Muscle Tester of the Lower Extremity in Children With Diplegia Cerebral Palsy
Objectives: The Micro Manual Muscle Tester (MMMT) is a Hand-Held Dynamometer (HHD). The current study aimed to evaluate the intra- and inter-rater reliability of this device. Methods: To determine the reliability of the MMMT, two previously trained assessors to work with HHD performed HHD measurements on 7 muscle groups of the lower extremities (hip flexors, hip extensors, hip abductors, knee ...
متن کاملمقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی
Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta of bioengineering and biomechanics
دوره 18 1 شماره
صفحات -
تاریخ انتشار 2016