Decellularization reduces the immune response to aortic valve allografts in the rat.

نویسندگان

  • Steven R Meyer
  • Jeevan Nagendran
  • Leena S Desai
  • Gina R Rayat
  • Thomas A Churchill
  • Colin C Anderson
  • Ray V Rajotte
  • Jonathan R T Lakey
  • David B Ross
چکیده

OBJECTIVES Cryopreserved valve allografts used in congenital cardiac surgery are associated with a significant cellular and humoral immune response. This might be reduced by removal of antigenic cellular elements (decellularization). The aim of this study was to determine the immunologic effect of decellularization in a rat allograft valve model. METHODS Brown Norway and Lewis rat aortic valves were decellularized with a series of hypotonic and hypertonic buffers, protease inhibitors, gentle detergents (Triton X-100), and phosphate-buffered saline. Valves were implanted into Lewis rats in syngeneic and allogeneic combinations. Cellular (CD3 and CD8) infiltrates were assessed with morphometric analysis, and the humoral response was assessed with flow cytometry. RESULTS Morphometric analysis identified a significant reduction in CD3 + cell infiltrates (cells per square millimeter of leaflet tissue) in decellularized allografts compared with that seen in nondecellularized allografts at 1 (79 +/- 29 vs 3310 +/- 223, P < .001), 2 (26 +/- 11 vs 109 +/- 20, P = .004), and 4 weeks (283 +/- 122 vs 984 +/- 145, P < .001). Anti-CD8 staining confirmed the majority of infiltrates were cytotoxic T cells. Flow cytometric mean channel fluorescence intensity identified a negative shift (abrogated antibody formation) for decellularized allografts compared with nondecellularized allografts at 2 (19 +/- 1 vs 27 +/- 3, P = .033), 4 (35 +/- 2 vs 133 +/- 29, P = .001), and 16 weeks (28 +/- 2 vs 166 +/- 54, P = .017). CONCLUSIONS Decellularization significantly reduces the cellular and humoral immune response to allograft tissue. This could prolong the durability of valve allografts and might prevent immunologic sensitization of allograft recipients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decellularization of rat aortic valve allografts reduces leaflet destruction and extracellular matrix remodeling.

OBJECTIVES Decellularization of aortic valve allografts in advance of transplantation is a promising approach to overcome immune-induced early graft failure. In this study the effects of in vitro cell extraction on extracellular matrix molecules and in vivo remodeling of decellularized aortic valves were investigated in a heterotopic aortic valve rat implantation model. METHODS Rat aortic val...

متن کامل

Decellularization of Rat Aortic Valve Allografts Reduces the Cellular Immune Response Resulting in a Structurally Intact Collagen Network Irrespective of Collagen Denaturation

Background There is increasing evidence that the immunogenicity of aortic valve allografts (AVA) is associated with valvular degeneration. Chemically induced cell extraction is expected to reduce an immune response. However, whether this will translate into reduced structural damage is unclear. The present study focussed at characterizing the immune response to cellular and acellular AVA and co...

متن کامل

eComment. Preoperative computed tomography scan for the proper planning of surgery for heart valve endocarditis.

[1] Byrne JG, Rezai K, Sanchez JA, Bernstein RA, Okum E, Leacche M et al. Surgical management of endocarditis: the society of thoracic surgeons clinical practice guideline. Ann Thorac Surg 2011;91:2012–9. [2] Acar C, Tolan M, Berrebi A, Gaer J, Gouezo R, Marchix T et al. Homograft replacement of the mitral valve. Graft selection, technique of implantation, and results in forty-three patients. J...

متن کامل

The effect of allogeneic or xenogeneic immune responses and preservation techniques on transplanted aortic valve grafts.

We examined the effect of allogeneic and xenogeneic immune responses on the histopathological changes in aortic valve grafts and the influence of preservation techniques on these changes. Brown Norway rats and Syrian hamsters were used as allogeneic and concordant xenogeneic donors of aortic valve grafts, respectively. The allografts and xenografts were implanted heterotopically in the abdomina...

متن کامل

Evaluation of humoral immune response to donor HLA after implantation of cellularized versus decellularized human heart valve allografts.

We have evaluated the development of antibodies in response to donor allograft valve implant in patients who received cellularized and decellularized allografts and determined possible immunogenic epitopes considered responsible for antibodies reactivity. Serum samples from all recipients who received cellularized allografts or decellularized allografts were collected before valve replacement a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 130 2  شماره 

صفحات  -

تاریخ انتشار 2005