The Influence of Thyristor Controlled Phase Shifting Transformer on Balance Fault Analysis
نویسنده
چکیده
This paper analyses the method to limit fault currents and pre fault bus voltage by the use of Thyristor Controlled phase Shifting transformer (TCPST). The mathematical model of power system equipped with TCPST was systematically derived. The magnitude of the series reactance plays a very important role to limit the short circuit current, as well as TCPST inject a series voltage which reduces the pre fault bus voltage. The total fault current of the system get reduced with respect to the total fault current of the system without introducing TCPST. The effectiveness of TCPST in the proposed method is investigated in the phase fault.
منابع مشابه
A Phase-Controlled 12-Pulse Rectifier with Unity Displacement Factor without Phase Shifting Transfor - Applied Power Electronics Conference and Exposition, 1998. APEC '98. Conference Proceedings 1998.,
This paper presents a three-phase 12-pulse phasecontrolled rectifier with unity displacement factor, low line current harmonic content, two quadrant operation and absence of phase shifting transformer. The circuit is composed by two three-phase 6-pulse rectifiers parallel connected by four balancing reactors. One is a conventional thyristor rectifier with a lag firing angle (a). The other is an...
متن کاملMulti-objective Optimal Placement with Multi-type Facts Devices for Thai Power System
-In this paper, multi-objective optimal placement (MOOP) of multi-type flexible AC transmission systems (FACTS) devices for Thailand power system is proposed. Four types of FACTS devices are used: thyristor-controlled series capacitor (TCSC), thyristor-controlled phase shifter (TCPS), unified power flow controller (UPFC), and static var compensator (SVC). The problem is decomposed into the opti...
متن کاملRecognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces
Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...
متن کاملTransient Stability Improvement Of Power System With Phase Shifting Transformer
Transient stability of a power system is concerned with the system’s ability to remain in synchronism after the disturbance is cleared. Occurrence of a fault in a power system causes transients. The disturbances subjected to the system may be occurrence of fault, sudden change in load etc. This paper describes the improvement of transient stability with phase shift insertion by phase shifting t...
متن کاملDiscrimination of Inrush from Fault Currents in Power Transformers Based on Equivalent Instantaneous Inductance Technique Coupled with Finite Element Method
The phenomenon of magnetizing inrush is a transient condition, which occurs primarily when a transformer is energized. The magnitude of inrush current may be as high as ten times or more times of transformer rated current that causes malfunction of protection system. So, for safe running of a transformer, it is necessary to distinguish inrush current from fault currents. In this paper, an equiv...