PURPOSE Aspirin and non-steroidal anti-inflammatory drugs (ASA/NSAIDs) are common causes of drug hypersensitivity. An oral provocation test is the only definitive diagnostic test. This study assessed the reliability of a flow cytometry-assisted basophil activation test (FAST) as a safe diagnostic method for ASA/NSAID-induced hypersensitivity, as its high sensitivity and specificity have been demonstrated for many other drugs. METHODS Eighteen patients and 11 controls were enrolled. Using a Flow-CAST kit® (Bühlmann Laboratories AG, Schönenbuch, Switzerland), 29 analyses with aspirin, ibuprofen, and diclofenac were performed by flow cytometry to detect double-positive staining of anti-IgE and anti-CD63. The stimulation index was defined as the activated basophil percentage after drug stimulation/basally active basophil percentage. A stimulation index≥2 and an absolute activated basophil percentage≥5 were considered positive. RESULTS Patients with hypersensitivity to ASA/NSAIDs were predominantly female, and the prevalence of atopy was higher in patients than in controls. A sensitivity of 61%, specificity of 91%, positive predictive value of 92%, and negative predictive value of 59% were achieved. CONCLUSIONS FAST is a useful additional method for diagnosis of hypersensitivity reactions to ASA/NSAIDs. Further development is required to increase the sensitivity of the test.
منابع مشابه
Recent applications of basophil activation tests in the diagnosis of drug hypersensitivity
Immediate-type drug hypersensitivity is an increasingly significant clinical issue; however, the diagnosis is frequently hindered due to lack of safe and precise diagnostic tests. Flow cytometry-assisted basophil activation test is a safe in vitro diagnostic tool for assessing basophil activation upon allergen stimulation. In this review, we have summarized current literature on the diagnostic ...
متن کامل378 Aspirin Desensitization Treatment: A Case Report
School of Marilia, São Paulo, Brazil; Flow Citometry, and; Dermatology, Medical School of Marilia, Marilia, Brazil. Background: The prevalence of hypersensitivity to nonsteroidal anti-inflammatory drugs (NSAIDs) is high and its in vitro diagnostic is a challenge. The basophil activation test with determination by flow cytometry (FC), of the expression rate of CD63 molecules has been much studie...
متن کاملIn vitro Tests: Basophil Activation Tests
In recent years, the quantification of basophil activation by flow cytometry (basophil activation test, BAT) has proven to be a useful tool for the assessment of immediate-type responses to allergens mediated by IgE or other mechanisms in drug-allergic patients. To date, most BAT studies reported in the literature have used CD69 or CD203c as markers to quantify basophil activation after antigen...
متن کاملThe basophil activation test by flow cytometry: recent developments in clinical studies, standardization and emerging perspectives
The diagnosis of immediate allergy is mainly based upon an evocative clinical history, positive skin tests (gold standard) and, if available, detection of specific IgE. In some complicated cases, functional in vitro tests are necessary. The general concept of those tests is to mimic in vitro the contact between allergens and circulating basophils. The first approach to basophil functional respo...
متن کاملBasophil activation test based on the expression of CD203c in the diagnostics of cow milk allergy in children
BACKGROUND Detection of allergen-induced basophil activation by flow cytometry has been shown to be a useful tool for allergy diagnosis. OBJECTIVE The aim of this study was to assess the potential of this technique for the diagnosis of pediatric cow milk allergy. MATERIAL AND METHODS The quantification of total and specific IgE and basophil activation test were performed to evaluate cow mil...