Removal of a Broken Cannulated Femoral Nail: A Novel Retrograde Impaction Technique

نویسندگان

  • Kongkhet Riansuwan
  • Direk Tantigate
  • Banchong Mahaisavariya
چکیده

This report presents a surgical technique to remove a broken cannulated nail from the femur. A Harrington rod was modified for retrograde impaction of the retained fragment. The broken implant was finally removed without complication. This particular procedure was safe, simple, and promising.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removal of a broken intramedullary femoral nail with an unusual pattern of breakage: a case report

To the best of our knowledge, only 3 cases, including the present case, have been reported with a three part broken pattern. However, this is the first case associated with a distal locking screw broken. We report the case of a 31-year-old patient who sustained an open femoral shaft fracture . The fracture was stabilized with a Kuntcher femoral nail. After 7 months of the initial surgery he pre...

متن کامل

Anterograde Removal of Broken Femoral Nails without Opening the Nonunion Site: A New Technique

OBJECTIVE We describe a new technique for removing the distal fragments of broken intramedullary femoral nails without disturbing the nonunion site. METHODS This technique involves the application of an AO distractor prior to the removal of the nail fragments, with subsequent removal of the proximal nail fragment in an anterograde fashion and removal of the distal fragment through a medial pa...

متن کامل

Removal of a Broken Cannulated Intramedullary Nail: Review of the Literature and a Case Report of a New Technique

Nonunion of long bones fixed with nails may result in implant failure. Removal of a broken intramedullary nail may be a real challenge. Many methods have been described to allow for removal of the broken piece of the nail. In this paper, we are reviewing the different techniques to extract a broken nail, classifying them into different subsets, and describing a new technique that we used to rem...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

  During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...

متن کامل

Breakage of a Lag Screw of Cephalomedullary Nail: A Technique of Removal

A broken lag screw of the cephalomedullary nail is a rare condition. Removal of the retained lag screw from the femoral head is also very challenging. This article describes a surgical technique and the modified instrument that was available in the operating room for removing the broken implant by closed technique.