Relation between impedance and endocardial contact during radiofrequency catheter ablation.

نویسندگان

  • S A Strickberger
  • V R Vorperian
  • K C Man
  • B D Williamson
  • S J Kalbfleisch
  • C Hasse
  • F Morady
  • J J Langberg
چکیده

Lesion size during radiofrequency catheter ablation in patients with paroxysmal supraventricular tachycardia (PSVT) is thought to be related to multiple factors, including contact pressure at the catheter-endocardial interface. Therefore a predictor of contact pressure at a potential target site for ablation might be useful. In this study 25 patients underwent duplicate 2 W applications of radiofrequency energy with the catheter in poor and firm contact with the right ventricular endocardium after successful ablation treatment for PSVT. The mean age of the patients was 44 +/- 15 years. Fifteen patients underwent slow pathway ablation for atrioventricular nodal reentrant tachycardia, and 10 patients underwent ablation for an accessory pathway. The mean impedance for low-energy applications in firm contact (139 +/- 24 ohms) was 22% +/- 13% greater (p 0.0001) than in poor contact with the right ventricle (113 +/- 16 ohms). The maximum impedance was 27% greater when the catheter was in firm (147 +/- 28 ohms) rather than poor contact (116 +/- 16 ohms), with the endocardium (p 0.0001). These results suggest that higher impedance measurements may be obtained with low-energy applications of 2 W when the ablation catheter is in firm contact with the endocardium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Angiographic and electrophysiological substrates for ventricular tachycardia mapping through the coronary veins.

OBJECTIVE To study the value of epicardial mapping through the coronary venous system in patients with sustained ventricular tachycardia. DESIGN 20 consecutive patients with sustained ventricular tachycardia who were candidates for radiofrequency ablation. SETTING Electrophysiological laboratory. INTERVENTIONS Coronary venous angiography was performed with a catheter, which provided coron...

متن کامل

First-in-human case of repeat pulmonary vein isolation by targeting visual interlesion gaps using the direct endoscopic ablation catheter after single ring pulmonary vein isolation

Gaps between radiofrequency (RF) ablation lesions are the culprits for failed pulmonary vein isolation (PVI) leading to recurrent atrial arrhythmias. The ability to directly visualize in real time and eliminate interlesion gaps may improve the success of RF ablation by achieving contiguous linear ablation lesion sets. We aimed to describe to the best of our knowledge the first reported clinical...

متن کامل

Radiofrequency catheter ablation guided by intracardiac echocardiography.

BACKGROUND Radiofrequency catheter ablation requires precise positioning of the ablation electrode. Fluoroscopically guided catheter manipulation has limitations, and there are risks of radiation exposure. The purpose of this study was to examine the feasibility of guiding catheter ablation within the right atrium with catheter-based intracardiac echocardiography. METHODS AND RESULTS A 10F, 1...

متن کامل

Target indices for clinical ablation in atrial fibrillation: insights from contact force, electrogram, and biophysical parameter analysis.

BACKGROUND In animal studies of radiofrequency ablation, lesion sizes plateau as the maximum lesion size is reached for an ablation. Lesion parameters are not available in clinical ablations, but preclinical work suggests that these correlate with impedance drop and electrogram attenuation. Characterization of the relationships between catheter contact force, ablation duration, and these surrog...

متن کامل

Impedance monitoring during radiofrequency catheter ablation in humans.

Radiofrequency catheter ablation of accessory pathways and the atrioventricular junction often requires multiple applications of energy. The inability to determine the effects of any given application on the underlying tissue may contribute to this problem. In the present study, impedance was monitored in 20 patients undergoing radiofrequency catheter ablation, and the relationship between an i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American heart journal

دوره 128 2  شماره 

صفحات  -

تاریخ انتشار 1994