Pulse wave variability within two short-term measurements.

نویسندگان

  • David Korpas
  • Jan Halek
چکیده

BACKGROUND Pulse wave analysis permits non-invasive assessment of indices of arterial elasticity. Decreased arterial elasticity results in higher pulse wave velocity and therefore earlier wave reflection. AIM The aim of this study was to evaluate the short-term variability for measurement of surface arteries. METHOD For detection of artery wall movement, a plethysmography method was used. The changes in artery volume, affecting the fluid behind the scanning membrane, transfer themselves into pressure changes and move towards the positive input of a sensitive differential pressure transducer. The output is carried to a notebook computer and analysed within the frequency and time domain. To correlate arterial pulse waves, the following parameters were used: relative crest time RCT, interwave distance IWD, dicrotic wave amplitude DWA and dicrotic wave time DWT. These parameters were analysed using Bland-Altman plots. RESULTS Two data points (5.6 %) fall outside the 2*SD range for both IWD and DWA parameters on posterior tibial artery and one data point (2.8 %) for DWT. Three data points (8.3 %) fall outside the 2*SD range for IWD and two data points for both DWA and DWT on the radial artery. Two data points fall outside the RCT measured on the ulnar artery, and all but one for IWD, DWA and DWT lie within the 2*SD range. CONCLUSIONS Pulse wave analysis showed reproducibility in a short-term study of all three measured distal arteries and is therefore suitable for use in patients for observing the progression of artery-wall-involving diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse rate variability is not a surrogate for heart rate variability.

To investigate the differences between heart rate (HR) variability and pulse rate (PR) variability, short-term variability of finger pulse wave and ECG signals were studied in 10 children with a fixed ventricular pacemaker rhythm (80 beats/min). Ten healthy children in sinus rhythm served as a reference population. Distal PR and HR were measured continuously using a Finapres device and an ECG r...

متن کامل

RESPIRATORY PHYSIOLOGY Short and long term variability of the interrupter technique under field and standardised conditions in 3–6 year old children

Background: The short and long term variability of the interrupter technique was assessed to determine whether interrupter resistance is a stable individual characteristic over time. The effect of field and standardised measurement conditions on the within-subject variability of the interrupter technique was also examined. Methods: The interrupter technique was studied under field and standardi...

متن کامل

Short and long term variability of the interrupter technique under field and standardised conditions in 3-6 year old children.

BACKGROUND The short and long term variability of the interrupter technique was assessed to determine whether interrupter resistance is a stable individual characteristic over time. The effect of field and standardised measurement conditions on the within-subject variability of the interrupter technique was also examined. METHODS The interrupter technique was studied under field and standardi...

متن کامل

Evidence for fractal correlation properties in variations of peripheral arterial tone during REM sleep.

Previous studies utilizing detrended fluctuation analysis (DFA) of heart rate variability during sleep revealed a higher fractal exponent during rapid eye movement (REM) sleep than non-REM sleep. The aim of this study was to determine whether the same difference exists in the variations of peripheral arterial tone (PAT). Finger pulse wave measured by a novel plethysmographic technique was monit...

متن کامل

Testing an association between baseline resting pulse rate averages and short-term changes in resting pulse rates: A pilot study.

INTRODUCTION Resting heart (pulse) rate (RPR) monitoring may be a useful neurological assessment tool in chiropractic practice. Lower RPR generally reflects a better level of fitness and health status than higher RPR. However, the clinical significance of short-term changes in RPR remains unknown. The purpose of this study was to take an initial step towards understanding the clinical significa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia

دوره 150 2  شماره 

صفحات  -

تاریخ انتشار 2006