Automatic Microaneurysm Quantification for Diabetic Retinopathy Screening
نویسندگان
چکیده
Microaneurysm is a key indicator of diabetic retinopathy that can potentially cause damage to retina. Early detection and automatic quantification are the keys to prevent further damage. In this paper, which focuses on automatic microaneurysm detection in images acquired through non-dilated pupils, we present a series of experiments on feature selection and automatic microaneurysm pixel classification. We found that the best feature set is a combination of 10 features: the pixel’s intensity of shade corrected image, the pixel hue, the standard deviation of shade corrected image, DoG4, the area of the candidate MA, the perimeter of the candidate MA, the eccentricity of the candidate MA, the circularity of the candidate MA, the mean intensity of the candidate MA on shade corrected image and the ratio of the major axis length and minor length of the candidate MA. The overall sensitivity, specificity, precision, and accuracy are 84.82%, 99.99%, 89.01%, and 99.99%, respectively. Keywords—Diabetic retinopathy, microaneurysm, naive Bayes classifier
منابع مشابه
Comparing SVM and Naïve Bayes Classifier for Automatic Microaneurysm Detections
Diabetic retinopathy is characterized by the development of retinal microaneurysms. The damage can be prevented if disease is treated in its early stages. In this paper, we are comparing Support Vector Machine (SVM) and Naïve Bayes (NB) classifiers for automatic microaneurysm detection in images acquired through non-dilated pupils. The Nearest Neighbor classifier is used as a baseline for compa...
متن کاملEarly Detection of Diabetic Retinopathy in Fluorescent Angiography Retinal Images Using Image Processing Methods
Introduction: Diabetic retinopathy (DR) is the single largest cause of sight loss and blindness in the working age population of Western countries; it is the most common cause of blindness in adults between 20 and 60 years of age. Early diagnosis of DR is critical for preventing vision loss so early detection of microaneurysms (MAs) as the first signs of DR is important. This paper addresses th...
متن کاملAutomatic Detection of Diabetic Retinopathy in Non-dilated RGB Retinal Fundus Images
In this paper, a method for automatic detection of microaneurysms in digital eye fundus image is described. To develop an automated diabetic retinopathy screening system, a detection of dark lesions in digital fundus photographs is needed. Microaneurysms are the first clinical sign of diabetic retinopathy and they appear small red dots on retinal fundus images. The number of microaneurysms is u...
متن کاملAutomatic non-proliferative diabetic retinopathy screening system based on color fundus image
BACKGROUND Non-proliferative diabetic retinopathy is the early stage of diabetic retinopathy. Automatic detection of non-proliferative diabetic retinopathy is significant for clinical diagnosis, early screening and course progression of patients. METHODS This paper introduces the design and implementation of an automatic system for screening non-proliferative diabetic retinopathy based on col...
متن کاملAutomatic Detection of Hard Exudates in Diabetic Retinopathy Using Morphological Segmentation and Fuzzy Logic
Retinal image analysis is an essential step in the diagnosis of various eye diseases. Diabetic Retinopathy (DR) is globally the primary cause of visual impairment and blindness in diabetic patients. Early diagnosis through regular screening and timely treatment has proven beneficial in preventing visual impairment and blindness. In this paper we have proposed a novel approach to automatically d...
متن کامل