Comparison of a Novel Weightbearing Cone Beam Computed Tomography Scanner Versus a Conventional Computed Tomography Scanner for Measuring Patellar Instability

نویسندگان

  • John Marzo
  • Melissa Kluczynski
  • Anthony Notino
  • Leslie Bisson
چکیده

BACKGROUND Conventional computed tomography (CT) images are routinely used for diagnosing patellofemoral instability and are obtained with the patient in a supine position, nonweightbearing, with the knee in full extension, and with leg muscles relaxed. A new portable extremity cone beam CT (CBCT) scanner has been developed that may allow for more accurate diagnosis, as imaging can be performed with the patient standing, the knee flexed, and with leg muscles active. PURPOSE/HYPOTHESIS The purpose of this study was to compare CT measurements of patellar alignment on a prototype scanner versus conventional scanner in patients with known patellar instability. The hypothesis was that the measurements obtained with the knee flexed and the patient weightbearing would be less than those obtained from the conventional CT scan. STUDY DESIGN Cross-sectional study; Level of evidence, 3. METHODS Twenty patients with a diagnosis of lateral patellar instability were imaged on both a conventional CT scanner and on a prototype CBCT scanner. Objective measures of patellofemoral alignment (tilt angle, congruence angle, tibial tuberosity-trochlear groove [TT-TG] offset) were assessed on images obtained from the prototype and conventional CT scans by 2 independent reviewers. Paired t tests were calculated to compare the mean measurement of patellofemoral alignment obtained from the prototype versus conventional CT. Interrater reliability was assessed using a 2-way mixed-effects model intraclass correlation coefficient (ICC) for tilt angle, congruence angle, and TT-TG offset on the prototype and conventional CT scans. RESULTS Measurements of patellofemoral alignment were significantly less when acquired by the new prototype CBCT scanner while subjects were weightbearing on a flexed knee. On the images from the prototype CBCT scan, the tilt angle averaged 18.2° ± 11.6° compared with 28.1° ± 7.1° on the conventional CT scan (P < .0001). The congruence angle was 3.0° ± 30.1° compared with 26.7° ± 18.1° on the conventional CT scan (P = .0002). Finally, the TT-TG offset distance averaged 12.3 ± 6.3 mm when measured on the CBCT scan compared with 20.1 ± 4.2 mm on the conventional CT scan (P < .0001). Good interrater reliability was found for tilt angle, congruence angle, and TT-TG offset on conventional and CBCT scans (ICC range, 0.79-0.96). CONCLUSION In patients with patellar instability, measurements of patellofemoral alignment are reduced on images obtained from a new weightbearing extremity CBCT scanner on a flexed knee versus conventional CT in the supine position with a fully extended knee. Improvement in objective measurements of patellar alignment should lead to improved clinical and surgical care of patients with this condition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Tibial Tuberosity–Trochlear Groove Offset Distance by Weightbearing Cone-Beam Computed Tomography Scan

Background Computed tomography (CT) scans are useful for objectively measuring bone alignment because they show bone detail particularly well, and these scans have been used extensively to assess patellar orientation. The tibial tubercle-trochlear groove (TT-TG) offset distance has been shown to be influenced by knee flexion and weightbearing, yet conventional CT scans are obtained with the sub...

متن کامل

مقایسه دقت توموگرافی سه‌بعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماری‌های سینوس پارانازال

Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Measuring the thickness of buccal cortical bone of maxillary premolar teeth by cone beam computed tomography technique

Background and Aims: Immediate implant placement following tooth extraction is a treatment with many advantages. Alveolar bone preservation after immediate implant, need minimum of 2 mm thickness in buccal bone plate. The aim of this study was to evaluate the thickness of buccal cortical bone of maxillary premolars by Cone Beam Computational Tomography (CBCT) technique. Materials and Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016