Combinatorial design of near-optimum masks for coded aperture imaging

نویسندگان

  • Axel Busboom
  • Harald Elders-Boll
  • Hans D. Schotten
چکیده

In coded aperture imaging the attainable quality of the reconstructed images strongly depends on the choice of the aperture pattern. Optimum mask patterns can be designed from binary arrays with constant sidelobes of their periodic autocorrelation function, the so{called URAs. However, URAs exist for a restricted number of aperture sizes and open fractions only. Using a mismatched lter decoding scheme, artifact{free reconstructions can be obtained even if the aperture array violates the URA condition. A general expression and an upper bound for the signal{to{noise ratio as a function of the aperture array and the relative detector noise level are derived. Combinatorial optimization algorithms, such as the Great Deluge algorithm, are employed for the design of near{optimum aperture arrays. The signal{to{noise ratio of the reconstructions is predicted to be only slightly inferior to the URA case while no restrictions with respect to the aperture size or open fraction are imposed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimizing wide-field coded aperture imaging: radial mask holes and scanning

Imaging at hard X-ray energies (~10-600 keV) over very large fields of view (~60 per telescope) is required to conduct a high sensitivity all-sky and all-time survey for black holes. The proposed Energetic X-ray Imaging Survey Telescope (EXIST) could achieve the high sensitivity required for the mission science objectives by scanning an array of wide-field coded aperture telescopes with apertur...

متن کامل

High-resolution, high sensitivity detectors for molecular imaging with radionuclides: The coded aperture option

Molecular imaging with radionuclides is a very sensitive technique because it allows to obtain images with nanomolar or picomolar concentrations. This has generated a rapid growth of interest in radionuclide imaging of small animals. Indeed radiolabeling of small molecules, antibodies, peptides and probes for gene expression enables molecular imaging in vivo, but only if a suitable imaging syst...

متن کامل

Sensitivity Matrix Coded Aperture Imaging Method

The standard coded aperture imaging approach assumes: • sources at infinity; • isolated point sources in specific directions; • masks with flat power spectrum (except for DC); • thin masks free of vignetting; • collimation to block rays from " out of view " directions; • visible sources cast full cycle of mask pattern on detectors; • use of correlation with the mask pattern to generate an image...

متن کامل

Improvements in coded aperture thermal neutron imaging

A new thermal neutron imaging system has been constructed, based on a 20-cm x 17-cm He-3 position-sensitive detector with spatial resolution better than 1 mm. New compact custom-designed position-decoding electronics are employed, as well as high-precision cadmium masks with Modified Uniformly Redundant Array patterns. Fast Fourier Transform algorithms are incorporated into the deconvolution so...

متن کامل

Design of Near-field Coded Aperture Cameras for High-resolution Medical and Industrial Gamma-ray Imaging

Coded Aperture Imaging is a technique originally developed for X-ray astronomy, where typical imaging problems are characterized by far-field geometry and an object made of point sources distributed over a mainly dark background. These conditions provide, respectively, the basis of artifact-free and high Signal-to-Noise Ratio (SNR) imaging. When the coded apertures successful in far-field probl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997